1. GENERAL FEATURES
Remove the appliance from the packaging, turn upside down and rest on the polystyrene.
Check that neither the appliance nor the power cable has been damaged in any way during tran-
sportation. Do not operate the appliance if damaged
2. FITTING THE FEET
Remove the feet and the castors from the polystyrene packing.
Fit the castors to the spindles on the feet and push firmly until they click into position (fig. 1).
Pull each castor to check that it is fitted correctly.
Fit the feet to the bottom of the radiator using the threaded bar and wing nut provided. Fit only
between the external elements as shown in figures 2, 3 and 4.
Model with foot without castor
Some models have one foot without castors. To mount, proceed as follows:
Mount the foot with castors following the above instructions, only between the external elements on
the side opposite to the controls (see figure 5).
Mount the foot without castors by inserting the two guides (A fig. 5) into the holes on the bottom of
the control box (fig. 5).
Fit the tooth into the slot provided and lock the foot with the eye screw (fig. 6). After fitting, turn the
radiator back into the vertical operating position.
Models with "Easy wheel" sytem
Turn the radiator upside-down on a rug or a soft surface in order to prevent damaging the
paint finish. Fully unfold the castors by turning them outwards (Fig.7).
Turn the radiator back to its upright position.

IMPORTANT

When in use, the radiator should always be kept vertical (wheels at the bottom, controls at the
top). Any other position could be dangerous!
3. ELECTRICAL CONNECTION
-
Before plugging the radiator into the mains, check that the voltage of your mains electricity sup-
ply corresponds to the value V indicated on the appliance and that the socket and power line
are appropriately dimensioned.
-
CONNECT THE RADIATOR TO EFFICIENTLY EARTHED SOCKETS ONLY
-
This appliance complies with EEC Directive 89/336 and D.M. 476/92, relating to electroma-
gnetic compatibility.
4. INSTRUCTIONS FOR USE
Switching on
Plug into the mains socket. Turn the thermostat to maximum. Switch the radiator on using the swit-
ch/switches following the procedures given in points a) - b).
a) Models with single switch (1 power level):
-
button in position «
-
button in position «O» = (indicator light off)
b) Models with double switch (3 power levels)
-
button in position «l» = minimum power (indicator light on);
-
button in position «ll» = intermediate power (indicator light on);
-
both buttons in position «l» «ll» = maximum power (indicator lights on)
To turn appliance off, switch off both switches or remove plug from wall socket.
Adjusting the thermostat
When the room has reached the required temperature, slowly turn the thermostat until the indicator
light goes off (or to the position marked by a click) and no further. The set temperature will then be
regulated automatically and kept constant by the thermostat.
Frost protection function
With the thermostat in position
temperature of about 5˚C, preventing freezing with minimum energy consumption.