Changing Back Tamper position:
The back tamper is by default secured on the right
side of the internal base (Rear view). If you wish to
move it to the left side (rear view), do the following
(Figure 5):
1. Remove tamper screw 1 in order to release the
tamper from position 7.
2. Ensure tamper spring (2) rests over tamper wire
base 4.
3. Ensure plastic tamper bracket (3) rests over
both 2 and 4.
4. Secure tamper screw (1) into (3) over position 6.
NOTES:
1.
Verify that you hear a "Click" when attaching the tamper spring to the wall.
2.
For pole installation, the tamper can be moved to the bottom right-hand side of the internal base.
Back Tamper Terminal Wiring
If you wish to use the back tamper (recommended) remove the short from the back tamper terminal
block and connect the back tamper wires to the back tamper terminal block.
Configuration Parameters
Via the RISCO panel or Configuration Software you can define the following parameter settings of your
detector according to your needs:
1. LEDs operation
On: LEDs enabled (Default: On)
Off: LEDs disabled
2. PIR Sensitivity: High/Low (Default: Low)
3. Mode: Normal/Walk Test (Default: Normal)
4. Supervision Time: 0-255 minutes (default: 15 mins)
For more information refer to the relevant RISCO panel Installer Guide.
BACK TAMPER
Back Tamper in use
Back Tamper not used
H1
Installation Manual
Figure 5
Left Side
Tamper
6
3
1
4
2
H1
Short
Right Side
Tamper
7
5
7