Product appearance is for reference
only and may differ from the actual
product.
Appearance (Page 2 – A)
There are two types of thermal sphere
positioning systems. Please take the actual
device for reference.
Cable Description (Page 2 – B)
1. RS-485
2. Network Cable: Connect the network
interface with network cable.
3. BNC: Connect video interface.
4. Alarm Cable: Connect terminal ALARM-IN
with terminal GND, and connect terminal
ALARM-OUT and terminal ALARM-COM.
5. Power Input Cable: Support 48 VDC power
supply.
Install the Camera (Page 3 – C)
The installation steps of the two types of
cameras are the same. Here is an installation
example of the type II camera.
Steps:
1. Move the device to the specified location in
either of the following ways.
a) Pull out the rubber plugs at the top of
the device, insert and fix the lifting rings to
the holes, and move the device to the
specified location with a lever or a crane.
b) Pull out the rubber plugs on the device
base, insert and fix the handheld carrying
poles to the holes, and then lift up and move
the device to the specified location.
2. Drill six holes on the bracket according to
the dimension of the bracket.
3. Take out six M10 × 50 screws, and fix the
device to the bracket with the screws.
4. Pull the horizontal positioning pin upward,
and rotate the positioning pin 90° clockwise
to unlock the device. You can hear a click if
the operation is successful.
5. Remove the lifting rings and handheld
carrying poles, and insert the rubber plugs
back.
6. Apply the anti-corrosion gel on the screws.
Install the Power Box (Page 4 – D)
Before you start the installation, prepare a
installation panel by yourself, and fix it at the
required place.
Method I: Vertical Installation
Steps:
1. Drill four φ 6.5 mm holes on the installation
panel according to the instruction in D – I –
1.
2. Screw four M6 screws into the installation
panel. Leave at least 5 mm space between
the screwhead and the installation panel.
3. Align the four bigger holes on the back
panel of the power box with the four screws,
move the power box downward to hang it
on the installation panel, and tighten the
screws to fix the power box.
4. Remove the waterproof covers and connect
the corresponding cables.
Method II: Horizontal Installation
Steps:
1. Drill four φ 6.5 mm holes on the installation
panel according to instruction
(as shown in D – I – 1).
2. Fix the power box on the installation panel
with four M6 screws.
Waterproof Method (Page 6 – E)
1. Install network cable waterproof jacket.
2. Use supplied waterproof tape to protect
cable connectors and unused cables.
Alarm Output (Page 7 – F)
1) Relay output
2) DC load
3) Power supply
4) JQC-3FG Relay
Activate and Access Network Camera
(Page 7 – G)
User Manual
Legal Information
© 2023 Hangzhou Microimage Software Co.,
Ltd. All rights reserved.
About this Manual
The Manual includes instructions for using
and managing the Product. Pictures, charts,
images and all other information hereinafter
are for description and explanation only. The
information contained in the Manual is subject
to change, without notice, due to firmware
updates or other reasons. Please find the
latest version of this Manual at the HIKMICRO
website (www.hikmicrotech.com).
Please use this Manual with the guidance and
assistance of professionals trained in
supporting the Product.
Trademarks
8
English