USER'S MANUAL AND OPERATING INSTRUCTIONS
C
ANS Z83.7-2017 CSA 2.14-2017
CONSTRUCTION HEATER
Adequate ventilation must be provided.
GHP Group, Inc.
6440 W Howard St
Niles, IL 60714-3302
GENERAL HAZARD WARNING
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH
THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS,
OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN. ASPHYXIATION, CARBON
MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD
USE OR SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTION
MANUAL, LABEL, ETC; CONTACT THE MANUFACTURER.
Questions, problems, missing parts? Before returning to your retailer, call our customer
service department at 877-447-4768 8:00 a.m. – 4:30 pm CST, Monday – Friday
PROPANE
CONSTRUCTION HEATER
Dyna-Glo® PRO MODEL:
LPFA43H, LPFA43H-01
(37,000/43,000 BTU/HR, FORCED - AIR)
US
CONSUMER: Retain this manual for future reference.
or email us at customerservice@ghpgroupinc.com
www.ghpgroupinc.com
Printed in China
LPFA43H/LPFA43H-01
IMLPF43H - MDP

Publicité

loading

Sommaire des Matières pour Dyna-Glo Pro LPFA43H

  • Page 1 PROPANE CONSTRUCTION HEATER USER’S MANUAL AND OPERATING INSTRUCTIONS Dyna-Glo® PRO MODEL: LPFA43H, LPFA43H-01 (37,000/43,000 BTU/HR, FORCED - AIR) ANS Z83.7-2017 CSA 2.14-2017 CONSTRUCTION HEATER Adequate ventilation must be provided. GHP Group, Inc. 6440 W Howard St LPFA43H/LPFA43H-01 Niles, IL 60714-3302...
  • Page 2 PROPANE CONSTRUCTION HEATER TABLE OF CONTENTS Introduction & Specifications ..........2 - 3 •...
  • Page 3 PROPANE CONSTRUCTION HEATER DYNA-GLO PROPANE FORCED AIR CONSTRUCTION HEATERS The heater is designed and approved for use as a construction heater under ANSI Z83.7 CSA 2.14. It is hard CHECK WITH YOUR LOCAL FIRE SAFETY to anticipate every use which may be made of this heater.
  • Page 4 PROPANE CONSTRUCTION HEATER USA 8-Hr Time weighted average Canada 8-hr time weighted average (OSHA 29 CFR 1926.55 App A) WorkSafe BC OHS Guidelines Part 5.1 and Ontario Workplaces Reg 833 50 ppm 25 ppm 5000 ppm 5000 ppm 3 ppm (Reg 833) Canada STEL (15 minutes Reg 833/1 hour USA –...
  • Page 5 PROPANE CONSTRUCTION HEATER GENERAL SAFETY INSTRUCTION Accidents are always tragic especially because so many of them could have been prevented with little care and judgment. There are some basic good practices, we hope you will follow for safe use of your heater. IMPORTANT SAFETY INSTRUCTION •...
  • Page 6 PROPANE CONSTRUCTION HEATER UNPACKING HEATER 1. Remove heater from carton. 2. Remove all protective packing applied to heater for shipment. 3. Retain cartons and packaging material until unit is operated and found in good condition. 4. Check heater for any shipping damage. If heater shows any external or internal damage, promptly inform dealer/distributor where you purchased heater.
  • Page 7 PROPANE CONSTRUCTION HEATER INFORMATION ON SIZE * CAPACITY OF PROPANE GAS CYLINDERS: The chart below shows the number and size of propane tanks needed to run this heater. *Less gas is vaporized at lower temperatures. You may need two or more 100 pound (45 kg) tanks or one larger tank in colder weather. (See the parts list for your model of heater to get the specified regulator assembly.) Number of Tanks Temperature...
  • Page 8 PROPANE CONSTRUCTION HEATER INSTALLATION TO THE PROPANE GAS TANK IMPORTANT: You must use a propane/LP gas supply cylinder that is compatible with the connection device provided with the hose and regulator. Regulator Propane/LP Supply Valve Propane/LP Fuel Gas Tank Fitting Hose to Heater Hose to Regulator...
  • Page 9 PROPANE CONSTRUCTION HEATER PROPANE SAFETY Propane is safe to use when properly handled. Careless handling of the Propane gas tank could result in fire and/or an explosion. Therefore: • Always keep tank/cylinder securely fastened in an upright position. • Avoid tipping tank on its side when connected to a regulator since this may cause damage to diaphragm in regulator.
  • Page 10 PROPANE CONSTRUCTION HEATER SHUTDOWN INSTRUCTIONS WARNING : Motor and fan must be running before lighting, during operation and at shutdown, in order to prevent a flame-out condition which could result in personal injury or property damage. Turn gas valve knob clockwise to OFF position.
  • Page 11 PROBLEM POSSIBLE   C AUSE CORRECTIVE   A CTION 1. Control   d ial   i s   o ff   a nd   u nit   i s 1. This   h eater   u ses   a   c on4nuous   s park 1.
  • Page 12 PROPANE CONSTRUCTION HEATER WIRING DIAGRAM / DIAGRAMME DES CÂBLE / DIAGRAMA DE CABLEADO WIRING DIAGRAM EARTH (SHELL) ENVELOPPE (EXTERIEURE) POWER CORD TIERRA (CUBIERTA) CORDON D'ALIMENTATION CABLE DE RELAY /RELAIS /RELEVADOR GREEN /VERT / VERDE ENERGIA BLACK / NOIR / NEGRO WHITE / BLANC / BLANCO...
  • Page 13 PROPANE CONSTRUCTION HEATER REPLACEMENT PARTS LIST MODEL: FA43 Series NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
  • Page 14 PROPANE CONSTRUCTION HEATER REPLACEMENT PARTS LIST PART NUMBER Article No. DESCRIPTION 43 SERIES INNER SHELL ASSEMBLY FA43-CR-02 NOZZLE FA43-CR-08 FLAME CAP FA43-CR-09 THERMAL SWITCH BRACKET 2304826 THERMAL SWITCH 2201373 SPARK ELECTRODE 2201375 HANDLE ASSEMBLY (BLACK) 2101447 HANDLE ASSEMBLY (GRAY) 2305426 OUTER SHELL FA43(ZS)-01-D MOTOR ASSEMBLY...
  • Page 15 WARRANTY LIMITED WARRANTY: This limited warranty is extended to the original retail purchaser of this Forced Air/Convection/Radiant Heater and warrants against any defect in materials and workmanship for a period of one (1) year from the date of retail sale (lifetime warranty for the brass nozzle burner only). GHP Group, Inc., at it’s option, will either provide replacement parts or replace or repair the unit, when properly returned to the retailer where purchased or one of our service centers as directed by GHP Group, Inc., within one (1) year of retail purchase.
  • Page 16 WARRANTY REGISTRATION IMPORTANT: We urge you to fill out your warranty registration card within fourteen (14) days of date of purchase. You can also register your warranty on the internet at www.ghpgroupinc.com. Complete the entire serial number. Retain this portion of the card for your records.
  • Page 17 RADIATEUR DE CONSTRUCTION AU GAZ PROPANE MANUEL DE L’USAGER ET INSTRUCTIONS D’OPÉRATION Dyna-Glo® PRO MODÈLE: LPFA43H, LPFA43H-01 (37,000/43,000 BTU/HR, AIR - PULSÉ) ANS Z83.7-2017 CSA 2.14-2017 RADIATEUR DE CONSTRUCTION Une ventilation adéquate est nécessaire. GHP Group, Inc. 6440 W Howard St...
  • Page 18 RADIATEUR DE CONSTRUCTION AU GAZ PROPANE TABLE DES MATIÈRES Introduction et caractéristiques ..........2 - 3 •...
  • Page 19 RADIATEUR DE CONSTRUCTION AU GAZ PROPANE RADIATEUR DE CONSTRUCTION AU GAZ PROPANE À AIR FORCÉ DYNA-GLO L’appareil de chauffage est conçu et approuvé pour être utilisé comme radiateur de construction en vertu de la norme ANSI Z83.7 CSA 2.14. Il est difficile de prévoir toutes les utilisations qui peuvent être faites de ce radiateur. VEUILLEZ CONSULTER LES AUTORITÉS LOCALES EN MATIÈRE DE SÉCURITÉ...
  • Page 20 RADIATEUR DE CONSTRUCTION AU GAZ PROPANE États-Unis – Concentration maximale Canada – Concentration maximale admissible admissible pour une exposition de 8 heures pour une exposition de 8 heures (lignes directrices (OSHA 29 CFR 1926.55 App A) en matière de santé et de sécurité au travail de WorkSafeBC, partie 5.1, et règlement 833 de l’Ontario) 25 ppm 50 ppm...
  • Page 21 RADIATEUR DE CONSTRUCTION AU GAZ PROPANE CONSIGNES DE SÉCURITÉ GÉNÉRALES Les accidents sont toujours tragiques, surtout parce que bon nombre d’entre eux pourraient être évités avec un peu d’attention et de jugement. Il existe quelques bonnes pratiques de base que vous devez suivre pour une utilisation sécuritaire de votre radiateur.
  • Page 22 RADIATEUR DE CONSTRUCTION AU GAZ PROPANE DÉBALLAGE 1. Retirez l’appareil de chauffage de la boîte. 2. Retirez tout emballage de protection appliqué au radiateur pour l’expédition. 3. Conservez les cartons et matériaux d’emballage jusqu’à ce que l’appareil soit mis en marche et que son bon état de fonctionnement soit constaté.
  • Page 23 RADIATEUR DE CONSTRUCTION AU GAZ PROPANE INFORMATION SUR LA TAILLE * CAPACITÉ DES BONBONNES DE GAZ PROPANE Le tableau ci-dessous indique le nombre et le format des bouteilles de gaz propane nécessaires pour faire fonctionner ce radiateur. *À des températures inférieures, une quantité moindre de gaz est dégagée.Par temps froid, vous pourriez avoir besoin de deux bouteilles (ou plus) de 45 kilos (100 livres) ou d’une plus grosse bouteille.
  • Page 24 RADIATEUR DE CONSTRUCTION AU GAZ PROPANE INSTALLATION À LA BOUTEILLE DE GAZ PROPANE IMPORTANT: Vous devez utiliser une bouteille de gaz propane (pétrole liquéfié) qui est compatible avec le dispositif de raccord fourni avec le tuyau et le régulateur. Régulateur Vanne d’alimentation en propane (pétrole liquéfié).
  • Page 25 RADIATEUR DE CONSTRUCTION AU GAZ PROPANE SÉCURITÉ RELATIVE AU PROPANE Le propane est sécuritaire lorsqu’il est manipulé correctement. Une manipulation négligente du réservoir de gaz propane peut entraîner un incendie et (ou) une explosion. Par conséquent : • Gardez toujours le réservoir (la bouteille), solidement fixé en position verticale. •...
  • Page 26 RADIATEUR DE CONSTRUCTION AU GAZ PROPANE DIRECTIVES D’ARRÊT AVERTISSEMENT Le moteur et le ventilateur doivent être en marche avant l’allumage, pendant le fonctionnement de l’appareil et à l’arrêt, afin de prévenir une extinction accidentelle qui pourrait causer des blessures ou entraîner des dommages matériels. Tournez le bouton de commande du gaz dans le sens horaire jusqu’à...
  • Page 27 PROBLÈME CAUSES   P OSSIBLES MESURE   C ORRECTIVE 1. Le   c adran   d e   r églage   e st   1. Ce1e   s itua4on   e st   n ormale.   C e   r adiateur   1.
  • Page 28 RADIATEUR DE CONSTRUCTION AU GAZ PROPANE WIRING DIAGRAM / DIAGRAMME DES CÂBLE / DIAGRAMA DE CABLEADO WIRING DIAGRAM EARTH (SHELL) ENVELOPPE (EXTERIEURE) POWER CORD TIERRA (CUBIERTA) CORDON D'ALIMENTATION CABLE DE RELAY /RELAIS /RELEVADOR GREEN /VERT / VERDE ENERGIA BLACK / NOIR / NEGRO WHITE / BLANC / BLANCO...
  • Page 29 RADIATEUR DE CONSTRUCTION AU GAZ PROPANE LISTE DES PIÈCES DE RECHANGE MODÈLE : FA43 Séries NE LAISSEZ JAMAIS L’APPAREIL DE CHAUFFAGE ALLUMÉ SANS SURVEILLANCE!
  • Page 30 RADIATEUR DE CONSTRUCTION RADIATEUR DE CONSTRUCTION AU GAZ PROPANE AU GAZ PROPANE LISTE DES PIÈCES DE RECHANGE NUMERO DE PIÈCE Article No. DESCRIPTION QTÉ 43 SÉRIES BOÎTIER FA43-CR-02 BUSE FA43-CR-08 BOUCHON DE FLAMME FA43-CR-09 SUPPORT DE THERMOCONTACTEUR 2304826 THERMOCONTACTEUR 2201373 ÉLECTRODES DE BOUGIE D’ALLUMAGE 2201375 ENSEMBLE POIGNÉE (NOIR)
  • Page 31 GARANTIE GARANTIE RESTREINTE: Cette garantie est offerte au premier acheteur du radiateur à air pulsé / rechaud rayonnant / radiateur à convection. Cette garantie couvre les défauts de fabrication et de matériel pendant une année (1) à compter de la date de vente au détail (garantie à vie pour la buse de brûleur en laiton seulement). En tel cas, GHP Group Inc.
  • Page 32 GHP Group, Inc. 6440 W Howard S Niles, IL 60714-3302 Tel: (877) 447-4768 www.ghpgroupinc.com GHP Group, Inc. 6440 W Howard St Niles, IL 60714-3302...