Note: After the battery has just been used, it must be left standing for 1 hour, and the
remaining capacity of the battery is checked in the following figure.
4. After connecting to the mains, the display shows "dFS", which means that the
desulfurization phase has been initiated and the device automatically goes into the state of
charge after about 5 minutes. During the charging process (start-stop/hydro-battery mode
without desulfurization phase), the display cyclically shows the battery voltage, current,
ambient temperature and current charging progress.
5. If the positive and negative terminals are connected incorrectly or incorrectly, the indicator
"Reverse polarity § -", EI-!- is displayed, and a buzzer beep sounds.
6. Select the charging mode suitable for the battery (see Mode Selection for details).
7. After charging is complete, the battery power bar on the screen is full (100%) and displays
FUL. It is recommended to continue charging for another 1 to 2 hours for a better effect and
turn off the standby screen.
8. After unplugging the power plug, first remove the positive and negative terminals to
complete the charging process.
Mode Selection
Every time the "Mode" button is pressed, the "Standard Start/Stop Water Battery Motorcycle
Repair" sequence is performed.
1. Suitable for ordinary lead-acid batteries/maintenance-free batteries.
2. Suitable for AGM/GEL/EFB batteries.
3. Suitable for water batteries and small lead-acid batteries.
4. Suitable for all kinds of motorcycles and small lead-acid batteries.
5. If the battery has not been used for a long time, is old or cannot be charged, select the
"Repair" mode. Mode to try to activate the battery.