Supplied parts
The following parts make up the LP conversion kit:
ORIFICES/ORIFICES/ORIFICIOS
LR(WHT)
RR(YEL)
CENTER
Out(PUR)
In(GRAY)
LF(WHT)
RF(RED)
DG69-00261B
DG96-00502B
(ASSY NOZZLE KIT)
NA30K6550T*/ NA36K6550T*
The all orifices' positions are marked on the provided sheet. The spud in the
pressure regulator is factory-installed for Natural Gas (NG) use. LP conversion
requires spud removal and reinstallation for LP use.
BURNER ORIFICE SIZES AND OUTPUT RATINGS
(LP Gas [Propane] 10 in WCP)
Burner Location
RF
LF
RR
LR
Center
1
Center
2
1
Model NA30K6550T* / NA36K6550T*
Model NA30K7750T* / NA36K7750T*
2
Install_NA9300K_DG68-00841A-01_EN+MES+CFR.indb 23
ORIFICES/ORIFICES/ORIFICIOS
LR(WHT)
RR(YEL)
CENTER
Out(WHT)
In(GRAY)
LF(WHT)
RF(RED)
DG69-00261A
DG96-00502A
(ASSY NOZZLE KIT)
NA30K7750T*/ NA36K7750T*
BTU Rate
Orifice size [mm]
11,500
1.04
7,500
0.83
4,000
0.62
7,500
0.83
14,500
In: 0.46 / Out: 0.74 (2 pcs)
16,500
In: 0.46 / Out: 0.83 (2 pcs)
BURNER ORIFICE SIZES AND OUTPUT RATINGS
(Natural Gas 5 in WCP)
Burner Location
BTU Rate
RF
13,000
LF
9,500
RR
5,000
LR
9,500
Center
19,000
1
Center
2
22,000
Model NA30K6550T* / NA36K6550T*
1
Model NA30K7750T* / NA36K7750T*
2
NOTE
Orifice markings:
115
115 – Denotes 1.15 mm orifice size opening.
Orifice size [mm]
1.64
1.40
1.01
1.40
In: 0.70 / Out: 1.30 (2 pcs)
In: 0.85 / Out: 1.36 (2 pcs)
English 23
12/12/2016 9:31:44 PM