DETAILED TEMPERATURE CONTROLLER
Front Panel Operation
Set temperature (the compressor's top temperature) adjustment:
1. Press the SET button, and the set temperature will be displayed, then press the UP or
DOWN arrow to store and memorize. Press the SET button to exit the adjustment
status and display the product temperature. If no more buttons are pressed within 6
seconds, the freezer product temperature will be displayed.
2. (Set temperature adjustment range: Parameter E1~E2)
Manually start/stop defrosting:
Press HI/LO button, then press the SET button and hold for 6 seconds to enter defrost status or to
stop defrost.
Display the sensor temperature (C13):
Press the DOWN arrow, and the product temperature (or cabinet temperature) will be displayed.
After 6 seconds, will resume normal display.
Refrigeration LED:
During refrigeration, the cooling snowflake LED is on. When the temperature is constant, the LED is
off.
Defrost LED:
During defrosting (if activated), the defrost LED is on. During the delay after defrosting, the LED
flashes.
Parameter set-up and settings (for all settings other than temperature setpoint):
Press the SET button and hold for 6 seconds to enter the parameter setting (flash and display
PAS). After entering the correct password (factory default is 15), press SET and the display will
show E1, E2, ...~do3 PAS in sequence. Press the UP or DOWN arrow and the value of the
parameter will be displayed and can be modified and stored. If no other buttons are pressed within
6 seconds, it will exit, and the new value will be stored. NOTE: Only when in the inner parameter
menu (display PAS) and the correct password is entered can the parameter value be adjusted. If
the wrong password is entered, the parameter modification menu will be exited, although the set
temperature adjustment is still active. If you forget the password, you will need to resume the factory
default settings.