Cyclic timer 230 V AC. It has a double time scale selectable by SW1 (scale A or B), ON and OFF time adjustable
independently between 5 seconds and 25 minutes with potentiometers. Activation by tension.
Operation : When the power is connected, the timer activates the relay for the set ON time and deactivates the relay
for the set OFF time. This sequence repeats cyclically as long as the circuit is powered.
POWER SUPPLY : Connect the 230 V AC power supply to the POWER terminal. Install a switch for circuit protection
and your own safety, according to CE standard. Before activating the switch, make the rest of the circuit connections.
Caution: Remember that there is 230 VAC in the circuit.
TIMING : To adjust the timing, select the time scale with SW -1, adjust ON time with potentiometer RV 1, adjust OFF
time with potentiometer RV2. Once these settings have been selected the timer is ready for use.
Timer activation : When the power is connected, the timer starts the ON – OFF work cycle.
www.cebek.com
-
Timer
Temporisateur
Temporizador
Temporitzador
I- 111
Technical characteristics
Voltage : 230 V. AC.
Medium Consumption : 1 W.
Timing configuration scale A : 5 to 150 secs.
Timing configuration scale B : 50 sec to 25 min.
Activation : voltaje
Operating Indicator Led : Yes.
Output type : Relay - NO / NC
Max. Output load : 7A ( 2A for inductive loads)
Sizes : 72 x 76 x 28 mm.
Weight : 143,70gr.
Din rail : C -7565
sat@fadisel.com