Robinet électronique

Publicité

F3EV1003, F3EV1005
Installation and operating
EN
instructions
Important notes
► All work must be carried out in a
de-energised state.
► Before installing flush piping system!
► The fitting must be operated only with
original mesh filters!
► The fitting must be checked and
maintained at regular intervals depending
on the water quality and in accordance with
the local conditions, and rules and
regulations applicable at the site.
Technical data
► Minimum flow pressure 1.0 bar
► Maximum operating pressure 10 bar
► Recommended flow pressure 1-5 bar
► Volume flow at 3 bar flow pressure 6 l/min
► maximum operating temperature
- continuous operation 70 °C
- short-term (<10 min) 80 °C
► F3EV1001: Voltage supply with lithium
battery CRP2 6 V DC
► F3EV1002, F3EV1003:
Supply voltage 110-240 V AC
► F3EV1005:
Supply voltage 6,75 / 12 V DC
► Power consumption 1,5 W
► Type of protection fitting IP 59K
DE
Montage- und Betriebsanleitung
Wichtige Hinweise
► Alle Arbeiten im spannungsfreien Zustand
durchführen
► Vor Installation Rohrleitungen spülen!
► Armatur nur mit original Sieb betreiben!
► In Abhängigkeit von der Wasserqualität,
den örtlichen Gegebenheiten und den vor
Ort geltenden Bestimmungen die Armatur
in regelmäßigen Abständen prüfen und
warten.
Technische Daten
► Mindestfließdruck 1,0 bar
► Maximaler Betriebsdruck 10 bar
► Empfohlener Fließdruck 1-5 bar
► Volumenstrom bei 3 bar Fließdruck 6 l/min
► maximale Betriebstemperatur
- Dauerbetrieb 70 °C
- Kurzzeit (<10 min) 80 °C
► F3EV1001: Spannungsversorgung
Lithium Batterie CRP2 6 V DC
► F3EV1002, F3EV1003:
Anschlussspannung 110-240 V AC
► F3EV1005:
Anschlussspannung 6,75 / 12 V DC
► Leistungsaufnahme 1,5 W
► Schutzart Armatur IP 59K