Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17
English
! The appliance must be installed by a qualified person in
compliance with the instructions provided.
!
Wear gloves when carrying out installation and
maintenance operations.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Warning: Failure to install the screws or fixing device in
accordance with these instructions may result in electrical
hazards.
The hood can look different to that illustrated in the
drawings in this booklet. The instructions for use,
maintenance and installation, however, remain the same.

AIR VENT

(for ducting versions)
! Prepare the hole and the air vent duct (150 mm
diameter).
! Use a duct of the minimum indispensible length.
! Use a duct with as few elbows as possible (maximum
elbow angle: 90°).
! Avoid drastic changes in the duct cross-section.
! Use a duct with an as smooth as possible inside.
! The duct must be made of certified material.
! Do not connect the hood to smoke exhaust ducts for the
products of combustion (boilers, fireplaces, stoves, etc).
! For the air vents comply with the provisions laid down by
the competent authorities.
In addition, the air must not be evacuated through a hole
in the wall unless specifically intended for this purpose.
! Fit air intakes in the room to prevent the hood from
creating a negative pressure in the room (which must
not exceed 0.04 mbar); if the hood is used at the same
time as non-electrical equipment (gas-, oil- and
charcoal-fired stoves, etc.) the exhaust gas may be
sucked in by the heat source.
FILTERING OR DUCTING VERSION ?
The hood may be in filtering or in ducting version. Decide
from the outset which type is to be installed.
For better efficiency, we recommend installing the hood in
the ducting version (if possible).
Ducting version
The hood purifies the air and evacuates it to the outside
through an exhaust duct (diameter 150 mm).
Version with an outside motor
In the version with an outside motor, a vacuum suction unit
must be connected; this exhaust will operate separately,
conveying the exhaust air through the unit. Only use
vacuum unitssuggested in the original catalogue.
Filtering version
The hood purifies the air and recycles the clean air back
into the room.
Only for hoods equipped with electronic control:
The 4th speed (intensive) is automatically lowered to 3rd
speed after 5 minutes of operation to optimise energy
consumption.
- If the hood is left on (lights and/or motor), after 10 hours in
the absence of commands from the user, it will
automatically switch to OFF condition with all services
switched off.
- The Buzzer emits a "beep" each time that a command is
set from the keyboard or remote control (optional).
- In the event of interruption of power during the hood, if you
restore the hood in the OFF state, then the engine must be
reactivate manually.
CONTROLS
Controls of Fig. 20
Button TC1 (Lights): Switches main light ON/OFFWhen the
main light is on, BL1 changes colour and becomes
active.When the button is pressed for more than a second,
it switches the courtesy lights (optional) on/off.
Button TC2 (Motor-V1): Motor ON/OFF - Activates the motor
at 1st speed.
Button TC3 (Motor-V2)Activates the motor at 2nd speed.
Button TC4 (Motor-V3)Activates the motor at 3rd speed.
Button TC5 (Motor-V4)Activates the motor at 4th
speedMaximum speed is timed at a maximum of 5
minutes, after which 3rd speed is set automatically.When
the motor is active, the LED of the last selected button
(TC2-TC5) active to signal which speed has been set.
Button TC6 (TIMER auto power off 5 min.)Activates the
TIMER function at the speed that has already been
selectedIf the motor is NOT active, it switches on the motor
at the 1st speed and activates the TIMER functionWhen the
TIMER function is active, BL6 becomes active.
30h filter ALARM: after 30 hours of operation, an alarm
switches on to signal the need for anti-grease filter
cleaning.The filter alarm, when active, is displayed for 30
sec each time the motor is deactiva-ted:BL6 remains
ON.During this period, it is possible to reset the alarm by
pressing the TC6 button for longer than a second.
120h filter ALARM: after 120 hours of operation, an alarm
switches on to signal the need for active carbon filter
(optional) replacement.The filter alarm, when active, is
displayed for 30 sec each time the motor is deactiva-
ted:BL6 lighting blinking.During this period, it is possible to
reset the alarm by pressing the TC6 button for longer than
a second.
Work Time Limit: if the hood is left on (lights and/or motor),
after 10 hours in the absence of commands from the user,
it will automatically switch to OFF condition with all services
switched off.
Buzzer: the Buzzer emits a "beep" each time that a
command is set from the keyboard or remote control
(optional).

Publicité

Table des Matières
loading

Table des Matières