Télécharger Imprimer la page

HIGH ONE VH 3 T 007C Consignes D'utilisation page 31

Publicité

Les langues disponibles

Les langues disponibles

C
1. The hob is equipped with a self diagnostic function. With
this test the technician is able to check the function
of several components without disassembling or
dismounting the hob from the working surface.
2. Failure code occur during customer using & Solution;
Failure
code
E0
Zero error.
Ceramic plate temperature sensor
E1
failure--open circuit.
Ceramic plate temperature sensor
E2
failure- -short circuit.
Ceramic plate temperature sensor
E7
failure.
High temperature of ceramic plate
C1
sensor.
Temperature sensor of the NTC
E3
failure --open circuit.
Temperature sensor of the NTC
E4
failure --short circuit.
Supply voltage is below the rated
EL
voltage.
Supply voltage is above the rated
EH
voltage.
EU
Communication error.
Useful information
Problem
No Auto-Recovery
24
Solution
Reinsert the connection between the
display board and the power board.
Replace the power board.
Check the connection or replace the
ceramic plate temperature sensor.
Wait for the temperature of ceramic
plate return to normal.
Touch "ON/OFF" button to restart unit.
Replace the display board.
Please inspect whether power supply
is normal.
Power on after the power supply is
normal.
Reinsert the connection between the
display board and the power board.
Replace the power board or the
display board.
EN

Publicité

loading

Ce manuel est également adapté pour:

983048