POWER : 12VDC. We recommend power supply CEBEK FE-113 or FE-300, which is perfectly suited to the needs of the circuit.
compatible transmitters: TL-300, TL-301, TL-420, TL-421, TL-428, TL-429, TL-432 . Supports extensions: TL-424 / TL-425.
Install a switch that are necessary for the protection and safety, as reflected in the CE standard.
A positive and negative supply to the corresponding input terminal.
ACTIVATION RESET : This occurs when you close the "RESET" terminal with the common negative terminal indicated by the
ground symbol COM. When "RESET 1 / 2/3/4", the corresponding relay will automatically switch to standby status, regardless of
the current order he was doing. The cable length should be as short as possible, if it is greater than 20 cm. you must use shielded
cable, connecting the shield to the corresponding terminal with the ground symbol.
ANTENNA : Must be installed before operating the remote control, we recommend the antenna Cebek C-0509 and C-0510 or 130
mm cable
ALIMENTATION : 12VDC. Nous recommandons l'alimentation CEBEK FE-113 - FE-300, ce qui est parfaitement adapté aux
besoins du circuit.
émetteurs compatibles: TL-300, TL-301, TL-420, TL-421, TL-428, TL-429, TL-432 . Prise en charge des extensions: TL-424 /
TL-425.
Installez un interrupteur qui sont nécessaires pour la protection et la sécurité, comme en témoigne la norme CE.
Une alimentation positive et négative à la borne d'entrée correspondante.
Power : 12 V .DC.
Maximum consumption : 250 mA.
Maxim output load : 7A (2A for indutive loads)
Reset input : Closure of contacts.
Antenna : 170 mm.
Working frequency : 433,92 Mhz.
LED indicators : Programming, Relays, Power
Relay Operation : Set Up in Monostable, bistable or Timed, (0,1 a 132 sec.)
Response time (Delay issuer order, relay response) : 0,5 seg
Compatibility : Issuers R.F. Group 3.
Weight : 99,4 gr.
Size : 87 x 107 x 17 mm.
DIN rail : C-7586
www.cebek.com
-
Receiver R.F
Récepteur R.F
Receptor R.F
Receptor R.F
4 Channels, group 3
TL-422
TECHNICAL CHARACTERISTICS
sat@fadisel.com