Télécharger Imprimer la page

HID iCLASS SE U90 Reader Guide D'installation page 3

Masquer les pouces Voir aussi pour iCLASS SE U90 Reader:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 5
iCLASS SE® U90 (U90.915 / U90.865)
2.
Wiring
TERMINAL
DESCRIPTION
P1-1
Beeper Input (BEEP)
P1-2
LED Input (GRN)
P1-3
Ground (GND)
P1-4
+VDC
P1-5
Unused (DRAIN)
P1-6
LED Input (RED)
P1-7
Hold Input (HOLD)
* Tamper Output - When activated, output synchronizes to ground (default).
** Dependent upon reader configuration. See the HTOG for Wiegand and Clock-in-Data configurations.
3.
Install Reader to Backbox
April 2018
TERMINAL
DESCRIPTION
P2-1
GPIO4 (RS485-Y / TXA)
P2-2
GPIO3 (RS485-Z / TXB)
P2-3
**Wiegand Data 0 / Data (DATA0/DATA)
P2-4
**Wiegand Data 1 / Clock (DATA1/CLK)
P2-5
*Open Collector Output / Tamper (OC/TMPR)
P2-6
GPIO2 (RS485-RXB)
P2-7
GPIO1 (RS485-RXA)
PLT-01545, Rev. A.4
ATTENTION
Observe precautions for handling
ELECTROSTATIC SENSITIVE DEVICES
TERMINAL
P3-1
Earth Ground
P3-2
Normally Closed (NC) - Relay 1
P3-3
Common (COM) - Relay 1
P3-4
Normally Open (NO) - Relay 1
P3-5
Normally Closed (NC) - Relay 2
P3-6
Common (COM) - Relay 2
P3-7
Normally Open (NO) - Relay 2
P3-8
Normally Closed (NC) - Relay 3
P3-9
Common (COM) - Relay 3
P3-10
Normally Open (NO) - Relay 3
DESCRIPTION
3

Publicité

loading

Ce manuel est également adapté pour:

Rdrseu90