Dr. Brown's
Cleaning and Assembly
• Fully disassemble all parts before each use.
• Thoroughly wash parts with hot soapy water and rinse.
• Rinse the lid, steam plate, and bottom of the Steam Sterilizer thoroughly
with clean water.
• Place the steam plate onto the bottom. (See Diagram A)
• Pour 6 ounces (180 mL) of water into the center of the bottom.
WARNING! Never put any liquid other than tap water into the sterilizer.
Note: Failure to add the right amount of water may cause damage to the products
and/or your microwave.
For Use With Wide-Neck Bottles and Related Parts
• Up to four wide-neck bottles can be sterilized at one time.
• Place the bottle neck facing downward and direct it into the round hole.
(See Diagram B)
• Insert the nipple/teat into the collar, then place it between the bottles.
(See Diagram C)
Note: After sterilization, hold the outer part of the bottle collar to assemble
to avoid nipple/teat contamination.
• Place the reservoirs onto the steam plate. (See Diagram D)
• Place the bottle caps onto the top of the reservoirs, and place the inserts
and travel disks onto the steam plate. (See Diagram E)
For Use With Narrow Bottles and Related Parts
• Up to four narrow bottles can be sterilized at one time.
• Insert the nipple/teat downward into bottle collar, then direct it into the
round hole. (See Diagram F)
Note: After sterilization, hold the outer part of the bottle collar to assemble
to avoid nipple/teat contamination.
• Place the inserts onto the middle of the steam plate. (See Diagram G)
• Place the bottle caps to cover the inserts on the steam plate. (See Diagram H)
• Place the bottles into bottle holder slots on the steam plate so that they are
supported at an approximately 45° angle. (See Diagram I)
• Place the reservoirs and travel disks onto the steam plate. (See Diagram J)
Microwave Instructions
• After properly positioning bottles and parts, place the lid on the sterilizer
and insert into microwave.
Note: The sterilizer should be placed in the center of the microwave.
• The exact time necessary to sterilize the bottles depends on the microwave
wattage. Please see the attached TABLE for the correct time.
WARNING! Before using, be sure to read complete Usage Instructions
provided with this sterilizer unit. When sterilizing, never use the unit without
the recommended amount of water. After sterilizing cycle, be sure to let the
unit cool for at least 10 minutes before handling. Be careful removing unit
from microwave after sterilizing cycle. Water in sterilizer will be hot.
Be sure to always hold sterilizer using the side handles. Do not try to lift
using the handle on the lid. There are four handles, use two on opposite sides
for stable grip. Mishandling the sterilizer could result in scalding. Keep out of
the reach of children.
Be sure to observe Cooling Time as sterilizer unit and water will be hot.
Sanitizing Timetable:
MICROWAVE
WATTAGE
500 W
700 W
900 W
1100 W
1250 W
1800 W
Fits ALL Dr. Brown's® bottles and most other bottle brands.
Microwave Steam Sterilizer
OPERATING INSTRUCTIONS
WATER
6 oz / 180 mL
6 oz / 180 mL
6 oz / 180 mL
6 oz / 180 mL
6 oz / 180 mL
6 oz / 180 mL
SANITIZING TIME
(MINUTES)
8
7
6
5
4
2
COOLING TIME
(MINUTES)
10
10
10
10
10
10