Télécharger Imprimer la page

K2 Pumps UTM01602K Manuel Du Propriétaire page 5

Publicité

Les langues disponibles

Les langues disponibles

NOTE: After starting, the pump will lower the water level to 1/ 4in. (6.4 mm) before losing suction. It will not pick up water
less than1/ 4in. (6.4 mm) deep when running and will not operate successfully if started in only 1/ 4in. (6.4 mm) of water.
AIRLOCK
This pump is a centrifugal utility pump, designed to efficiently remove water.
However, it cannot move air. If airis trapped inside the pump (a condition
called"airlock"), the pump cannot pump water out even thoughthe pump is
completely submerged. This pump has an anti-airlock hole. Air flows out
through the anti-airlock hole, eliminating the airlock so that the pump can operate
properly. If debris blocks the anti-airlock hole, unplug the pump, clean out the
anti-airlock hole, and restart thepump. Alternately, drain the water out of the
garden hose, keep the end of the hose out of the water, and plugin the power
cord, restarting the pump.
CAUTION: This hole is for anti-airlock purposes. Leakage of air or water is
NORMAL.
DO NOT BLOCK THIS HOLE!
CARE AND CLEANING
CAUTION:Always use the handle to lift the pump. Never use the power cord to lift the pump. To avoid skin burns, unplug
the pump and allow time for it to cool after periods of extended use.
Do
When the power is disconnected, inspect the pump
suction screen and remove all debris, then plug the
pump back into the grounded (GFCI) outlet.
To clean a pump clogged with debris:
Unplug the pump from electrical power.
Unscrew the stainless screws(7), and remove the bottom plate(6)
Unscrew the stainless screws(5), and remove the volute(4)and
gasket(3)
Use a flathead screwdriver to hold the shaft (1), then turn the
impeller (2) counterclockwise to release the impeller (2). Remove
debris from around the shaft (1) and on/under the impeller (2).
Reassemble.
For Professional Technical Support call 1-844-242-2475
Do Not
Do not disassemble the motor housing. This motor has
NO repairable internal parts, and disassembly may
cause leakage or dangerous electrical wiring issues.
Do not lift up the pump by the power cord.
5

Publicité

loading

Ce manuel est également adapté pour:

Utm02502k