Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16
D
F
ISPLAYING THE
The current flow rate in litres per minute can be
read out at the flow LED (10).
Number of burning
LEDs
1
2
3
4
5
M
AINTENANCE AND
Before beginning any maintenance or cle-
aning work, make sure that the device has
been unplugged and take precautions to ensure
that it cannot be switched on during work!
Cleaning the pump
– If you have used your domestic water system
to pump chlorine water (swimming pool water)
or liquids which leave a residue, flush your
pump out with clear water after use.
T
D
ECHNICAL
ATA
Type
Product number
Rated power
Power supply
Frequency
IP class
Noise emission
Max. suction height
Max. pump height
Max. flow rate
Max. temperature
of liquid pumped
Pump drive
Suction/pressure hose
Weight
See Figure D for the characteristic curve of your domestic water pump.
R
LOW
ATE
Flow rate
in l/min
> 1.5 - 2
> 4.0 - 6
> 18 - 20
> 36 - 40
> 48 - 52
C
LEANING
HWA 800
110 964
800 W
230-240 V
50 Hz
IPX4
9 m
42 m/4.2 bar
3600 l/h
35 °C
single stage
1"
8.1 kg
Cleaning blockages
If your domestic water pump should become
block-ed so that it does not suction or pump out
liquid, remove the obstruction as follows:
• Remove the suction hose from the pump inlet.
• Unscrew and remove the suction hose
connector (1) with the built-in non-return valve
(2).
• Attach the pressure hose connector (4) to the
water tap and spray water into the pump until
the blockage is flushed out.
• If the pump runs trouble-free when turned on
for a short time, put it into operation as described
in the instructions.
Make sure that the non-return valve is inser-
ted properlz when replacing the suction hose.
• Screw the suction hose connector (1) with the
inserted non-return valve (2) into the pump inlet.
• Put the pump into operation as described in the
instructions.
Frost protection
Your domestic water pump is susceptible to low
temperatures. Make sure to empty the device of
residual liquid (hoses and pump) and store it so
that it is protected from frost.
• Empty the suction and pressure hoses.
• Remove the draining screw (12) and drain all
water from the pump.
• Replace the draining screw and store the device
so that it is protected from frost.
GPI 900/3
GPI 1100/4
110 938
900 W
230-240 V
50 Hz
IPX4
< 58 dB(A)
8 m
35 m/3.5 bar
45 m/4.5 bar
5100 l/h
35 °C
3 stage
1"
11 kg
GPI 5100/3
110 937
1100 W
230-240 V
230-240 V
50 Hz
IPX4
< 58 dB(A)
< 58 dB(A)
8 m
38 m/3.8 bar
5100 l/h
35 °C
4 stage
1"
11 kg
GB
112 142
900 W
50 Hz
IPX4
8 m
5100 l/h
35 °C
3 stage
1"
11 kg
13