2.4
Commissioning
Before start-up:
1. Observe technical data, figures, item
numbers, intended use and safety in-
structions
(see Instruction manual, Part 1, Chap-
ter: "Technical data" and the "Intended
use" chapter).
2. Carry out a visual inspection.
3. Do not use below 5° C.
For use with cartridges or silicone
puppets, see Instruction manual
Part 1.
Compressed air connection:
1. Connect a filter pressure reducer up-
stream of the filter.
2. Press the quick-action coupling of the air
hose onto the plug nipple (item 01)
(Figure 1a).
Operation:
1. Close the air regulation (item 03) by
turning it towards the right (Figure 4).
2. Press the trigger lever (item 02) and ad-
just the air regulation (item 03) for the
discharge speed of the silicone.
3. Release the trigger lever (item 02). Sili-
cone is depressurised automatically.
4. If present: rotating housing (item 04)
can be rotated manually during work and
adapted to the direction change of the
silicone string.
After use:
1. Disconnect the quick-action coupling
from
the
plug
(Figure 1b).
2. Clean the housing (item 04) immediate-
ly.
3. If present : clean the rubber piston
(item 07), telescope piston (item 08),
check the safety chain for secure fit.
nipple
(item 01)
2.5
Maintenance
Prevent stiffness, leaks: lubricate the valve
pin and pivot point on the trigger lever
(Pos. 02).
Apply a light coat of oil to the valve
pin.
If present, lubricate the outside of the tele-
scope piston (item 08) while it is pulled out
(see Figure 7).
2.6
Decommissioning
Storage: Clean, dry, free from dust, above
5° C.
Disposal: Dispose of packaging / machine
according to valid statutory regulations.
2.7
Spare parts service
Visit
our
website
tems.com/td/ for the latest version of all ex-
ploded drawings and spare parts lists for our
products. If you have any special questions,
please consult the Schneider Airsystems Ser-
vice centre in your country (addresses in the
service appendix) or your local dealer.
2.8
Warranty conditions
Basis for warranty claims: complete unit
in original condition/proof of purchase.
According to legal provisions, you re-
ceive the following warranty against
material and manufacturing defects:
private use only: 2 years,
commercial use: 1 year.
Excluded from warranty claims: Wear or
expendable parts, improper use, overloading
/ incorrect pressure, manipulation / inappro-
priate use, inadequate / incorrect / lack of
maintenance or lubrication, bumps / im-
pacts, dust / dirt accumulation, unauthorised
/ incorrect working procedures, incorrect
power supply, impure / insufficiently filtered
compressed air, failure to read the instruc-
tion manual, incorrect operating resources /
materials.