1.
The sensing range is adjusted by pressing the teach-in button (approx. 1-3 sec‐
onds) until the yellow LED flashes.
1...3 sec.
2.
Depending on the requirements, the potentiometer can be used for fine-tuning
(without pressing the teach-in button).
Clockwise rotation: Sensing range increased
Counterclockwise rotation: Sensing range reduced
The sensing range can also be adjusted using just the potentiometer.
We recommend placing the object within the sensing range. Once the sensing
range has been adjusted, the object is removed from the path of the beam,
which causes the background to be suppressed. The digital output changes
table
3).
NOTE
WTB12V: After teach-in, approx. 1/3 of the linear light spot must be covered for
the sensor to switch. The sensitivity can be adjusted by turning so that the sensor
also switches with less coverage.
The sensor is adjusted and ready for operation.
NOTE
Configuration via BluePilot is also shown in a video:
Please refer to the enclosed "IO-Link photoelectric sensors" operating instructions for
information about adjusting the IO-Link sensing range.
(see
8027714.1HYU/2023/04/25 | SICK
Subject to change without notice