Room temperature,
ventilation
and cavity depth
Ambient temperature
The appliance is designed for a specific
climate class. Depending on the climate
class, the appliance can be operated at
the following temperatures.
The climate class can be found on
the rating plate. Fig. /
Climate class Permitted ambient temperature
+10 °C to 32 °C
SN
+16 °C to 32 °C
N
+16 °C to 38 °C
ST
+16 °C to 43 °C
T
Note
The appliance is fully functional within
the room temperature limits of the
indicated climatic class. If an appliance
of climatic class SN is operated at
colder room temperatures, the appliance
will not be damaged up to a temperature
of +5 °C.
Ventilation
The air on the rear panel of the appliance
heats up. Conduction of the heated air
must not be obstructed.
Otherwise, the refrigeration unit must
work harder. This increases power
consumption. Therefore: Never cover
or block the ventilation openings!
Cavity depth
A cavity depth of 560 mm is
recommended for the appliance.
If the cavity depth is smaller –
at least 550 mm – the energy
consumption increases slightly.
22
Installation location
Install the appliance in a dry, well
ventilated room. The installation location
should neither be exposed to direct
sunlight nor near a heat source,
e. g. a cooker, radiator, etc. If installation
next to a heat source is unavoidable,
use a suitable insulating plate or observe
the following minimum distances to a
heat source:
3 cm to electric or gas cookers.
30 cm to an oil or coal-fired cooker.
Connecting
the appliance
After installing the appliance, wait at least
1 hour until the appliance is switched on.
During transportation the oil in
the compressor may have flowed into
the refrigeration system.
Before switching on the appliance for
the first time, clean the interior of
the appliance (see chapter "Cleaning
the appliance").
Electrical connection
The socket must be near the appliance
and also freely accessible following
installation of the appliance.
The appliance complies with the
protection class I. Connect the appliance
to 220–240 V/50 Hz alternating
current via a correctly installed socket
with protective conductor. The socket
must be fused with a 10 to 16 A fuse.