NS2H-DUSK TO DAWN FLOOD LIGHT
INSTALLATION INSTRUCTIONS
ELECTRICAL SHOCK HAZARD
WARNING
Disconnect the Electrical supply power at the service panel (fuse or circuit breaker box) prior to installa�on. Failure to do so could result in serious injury or
death. Only qualified electricians should install this fixture and the installa�on MUST conform to the Canadian Electrical Code Part I and all local codes and
ordinances. Ensure that only proper tools, materials, and equipment are used to complete the installa�on.
SAFETY
•
Proper grounding is required to ensure personal safety.
•
Fixture should be mounted in loca�ons where unauthorized personnel will not readily subject it to tampering.
•
Do not use this equipment for anything other than its intended purpose.
•
Servicing this equipment should be performed by qualified service personnel.
•
Save these instruc�ons.
•
MIN 75 °C SUPPLY CONDUCTOR
INCLUDED IN THE BOX
•
Light fixture with twin light heads
•
Wall gasket
•
Metal Moun�ng bracket
•
Screws and Wire nuts
INSTALLATION
1.
Remove exis�ng light fixture as well as any exis�ng metal moun�ng bracket
(if any). [Fig. 1]
**NS2H is designed to be installed on a standard round junc�on box. If there is no exis�ng
junc�on box, please hire a licensed electrician to install one.
2.
Remove the center rubber plug and unscrew the Center moun�ng screw to
remove the moun�ng bracket. [Fig. 1]
3.
Secure the moun�ng bracket to the junc�on box with provided screws (2).
[Fig. 2]
4.
A�ach the Wall Gasket to the back of the fixture. Use the provided Aircra�
support cable to hang the fixture from the moun�ng bracket. [Fig. 3]
RAB Design Ligh�ng inc.
READ, UNDERSTAND
FOLLOW
, and
these instruc�ons before
installing the equipment
.
TOOLS REQUIRED
•
#2 Philips Screwdriver
Rubber Plug
Center Moun�ng Screw
[
1]
Fig.
[
2]
Fig.
[
3]
Fig.
August – 2023
NS2H-DUSK TO DAWN FLOOD LIGHT
INSTALLATION INSTRUCTIONS
5. Wiring Connec�on: Use provided wire nut to connect the fixture wires to
the supply wires following local building code and the following wiring
diagram [
Refer to your local electrical code for approved grounding method if exis�ng
house supply wire does not include ground wire.
•
Check that the line voltage is correct.
•
Connect fixture GROUND (green) wire to power supply GROUND (green) wire.
•
Connect fixture WHITE wire to power supply NEUTRAL wire.
•
Connect fixture BLACK wire to power supply LINE wire.
6.
Align the light fixture and wall gasket over the junc�on box and �ghten the center
moun�ng screw.
7.
Please inspect to ensure all the gap between fixture and junc�on box is sealed
Moun�ng bracket
by the wall gasket. Apply silicone caulking (not included) to seal any gap between
the light fixture and the moun�ng surface.
8.
Aim twin-head lights to desired loca�on and adjust sensor se�ngs.
CONTROLS
Refer to [Fig. 6]
•
BRIGHTNESS: Changes the brightness of the twin head lights
o
o
•
PHOTOCELL: Changes Day light sensor sensi�vity
o
Standard Junc�on Box
o
(not provided)
•
COLOUR: Changes the colour of the twin head lights
o
o
Moun�ng bracket
o
Refer to Fig.6 for recommended settings.
TROUBLESHOOTING
LIGHT WILL NOT TURN ON
•
Fixture not receiving power. If the fixture is wired to a switch, ensure it is turned on.
•
Incorrect wiring. Verify that the wires are connected properly using the diagram [Fig. 4].
•
Breaker/fuse. Ensure the fixture has not caused a blown fuse or triggered the breaker. Change the fuse or reset breaker if necessary.
•
Photocell ac�vated. If there is low ambient light but the fixture is not on, reduce the photocell sensi�vity using the PHOTOCELL dial.
LIGHT TURNS ON RANDOMLY AND/OR WILL NOT TURN OFF
Photocell ac�vated. If the fixture is s�ll ON in the bright ambient light, increase the photocell sensi�vity using the PHOTOCELL dial.
•
Aircra� Cable
LIGHT IS FLASHING
Support
•
Photocell ac�vated. Lights from fixture may be reflec�ng off a surface or other sources which is triggering the photocell. Try
reposi�oning the twin heads and/or decrease the photocell sensi�vity using the PHOTOCELL dial.
Wall gasket
Page 1 of 4
RAB Design Ligh�ng inc.
4] [Fig. 5]
Fig.
[
4]
Fig.
Le�: Lowest light level
Right: Highest light level
Le�: Lowest sensi�vity – this se�ng is applicable to turn ON light at
day�me
Right: Highest sensi�vity to turn on light at very dark ambient
condi�on
Le�: Warm (3000K)
Middle: Cool (4000K)
Right: Daylight (5000K)
August – 2023
Green:
White:ACN
Black:ACL
[
5]
Fig.
Daylight sensor
(Photocell)
[
6]
Fig.
Page 2 of 4