Télécharger Imprimer la page

RAB Design NS2H Instructions D'installation

Éclairage du crépuscule à l'aube

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

NS2H-DUSK TO DAWN FLOOD LIGHT
INSTALLATION INSTRUCTIONS
ELECTRICAL SHOCK HAZARD
WARNING
Disconnect the Electrical supply power at the service panel (fuse or circuit breaker box) prior to installa�on. Failure to do so could result in serious injury or
death. Only qualified electricians should install this fixture and the installa�on MUST conform to the Canadian Electrical Code Part I and all local codes and
ordinances. Ensure that only proper tools, materials, and equipment are used to complete the installa�on.
SAFETY
Proper grounding is required to ensure personal safety.
Fixture should be mounted in loca�ons where unauthorized personnel will not readily subject it to tampering.
Do not use this equipment for anything other than its intended purpose.
Servicing this equipment should be performed by qualified service personnel.
Save these instruc�ons.
MIN 75 °C SUPPLY CONDUCTOR
INCLUDED IN THE BOX
Light fixture with twin light heads
Wall gasket
Metal Moun�ng bracket
Screws and Wire nuts
INSTALLATION
1.
Remove exis�ng light fixture as well as any exis�ng metal moun�ng bracket
(if any). [Fig. 1]
**NS2H is designed to be installed on a standard round junc�on box. If there is no exis�ng
junc�on box, please hire a licensed electrician to install one.
2.
Remove the center rubber plug and unscrew the Center moun�ng screw to
remove the moun�ng bracket. [Fig. 1]
3.
Secure the moun�ng bracket to the junc�on box with provided screws (2).
[Fig. 2]
4.
A�ach the Wall Gasket to the back of the fixture. Use the provided Aircra�
support cable to hang the fixture from the moun�ng bracket. [Fig. 3]
RAB Design Ligh�ng inc.
READ, UNDERSTAND
FOLLOW
, and
these instruc�ons before
installing the equipment
.
TOOLS REQUIRED
#2 Philips Screwdriver
Rubber Plug
Center Moun�ng Screw
[
1]
Fig.
[
2]
Fig.
[
3]
Fig.
August – 2023
NS2H-DUSK TO DAWN FLOOD LIGHT
INSTALLATION INSTRUCTIONS
5. Wiring Connec�on: Use provided wire nut to connect the fixture wires to
the supply wires following local building code and the following wiring
diagram [
Refer to your local electrical code for approved grounding method if exis�ng
house supply wire does not include ground wire.
Check that the line voltage is correct.
Connect fixture GROUND (green) wire to power supply GROUND (green) wire.
Connect fixture WHITE wire to power supply NEUTRAL wire.
Connect fixture BLACK wire to power supply LINE wire.
6.
Align the light fixture and wall gasket over the junc�on box and �ghten the center
moun�ng screw.
7.
Please inspect to ensure all the gap between fixture and junc�on box is sealed
Moun�ng bracket
by the wall gasket. Apply silicone caulking (not included) to seal any gap between
the light fixture and the moun�ng surface.
8.
Aim twin-head lights to desired loca�on and adjust sensor se�ngs.
CONTROLS
Refer to [Fig. 6]
BRIGHTNESS: Changes the brightness of the twin head lights
o
o
PHOTOCELL: Changes Day light sensor sensi�vity
o
Standard Junc�on Box
o
(not provided)
COLOUR: Changes the colour of the twin head lights
o
o
Moun�ng bracket
o
Refer to Fig.6 for recommended settings.
TROUBLESHOOTING
LIGHT WILL NOT TURN ON
Fixture not receiving power. If the fixture is wired to a switch, ensure it is turned on.
Incorrect wiring. Verify that the wires are connected properly using the diagram [Fig. 4].
Breaker/fuse. Ensure the fixture has not caused a blown fuse or triggered the breaker. Change the fuse or reset breaker if necessary.
Photocell ac�vated. If there is low ambient light but the fixture is not on, reduce the photocell sensi�vity using the PHOTOCELL dial.
LIGHT TURNS ON RANDOMLY AND/OR WILL NOT TURN OFF
Photocell ac�vated. If the fixture is s�ll ON in the bright ambient light, increase the photocell sensi�vity using the PHOTOCELL dial.
Aircra� Cable
LIGHT IS FLASHING
Support
Photocell ac�vated. Lights from fixture may be reflec�ng off a surface or other sources which is triggering the photocell. Try
reposi�oning the twin heads and/or decrease the photocell sensi�vity using the PHOTOCELL dial.
Wall gasket
Page 1 of 4
RAB Design Ligh�ng inc.
4] [Fig. 5]
Fig.
[
4]
Fig.
Le�: Lowest light level
Right: Highest light level
Le�: Lowest sensi�vity – this se�ng is applicable to turn ON light at
day�me
Right: Highest sensi�vity to turn on light at very dark ambient
condi�on
Le�: Warm (3000K)
Middle: Cool (4000K)
Right: Daylight (5000K)
August – 2023
Green:
White:ACN
Black:ACL
[
5]
Fig.
Daylight sensor
(Photocell)
[
6]
Fig.
Page 2 of 4

Publicité

loading

Sommaire des Matières pour RAB Design NS2H

  • Page 1 Aim twin-head lights to desired loca�on and adjust sensor se�ngs. (if any). [Fig. 1] Daylight sensor **NS2H is designed to be installed on a standard round junc�on box. If there is no exis�ng CONTROLS (Photocell) junc�on box, please hire a licensed electrician to install one.
  • Page 2 NS2H-ÉCLAIRAGE DU CRÉPUSCULE À L'AUBE NS2H-ÉCLAIRAGE DU CRÉPUSCULE À L'AUBE INSTRUCTIONS D'INSTALLATION INSTRUCTIONS D'INSTALLATION 5. Connexions de câblage: U�lisez l'écrou fourni pour connecter les fils de l'appareil LIRE, COMPRENDRE et SUIVRE aux fils d'alimenta�on conformément au code du bâ�ment local et au schéma de ces instruc�ons avant...