Télécharger Imprimer la page

Samsung NA36N9755TS/AA Manuel D'installation page 23

Publicité

Les langues disponibles

Les langues disponibles

Supplied parts
The following parts make up the LP conversion kit:
ORIFICES/ORIFICES/ORIFICIOS
LR(WHT)
LF(WHT)
DG69-00399C
NA30N9755T*/NA36N9755T*
The all orifices' positions are marked on the provided sheet. The spud in the
pressure regulator is factory-installed for Natural Gas (NG) use. LP conversion
requires spud removal and reinstallation for LP use.
BURNER ORIFICE SIZES AND OUTPUT RATINGS
(LP Gas [Propane] 10 in WCP)
Burner Location
RF
LF
RR
LR
Center
Install_NA36N9755TM_DG68-01092A-01_EN+MES+CFR.indb 23
RR(YEL)
CENTER
Out(WHT)
In(GRAY)
RF(RED)
DG96-00686C
(ASSY NOZZLE-KIT)
BTU Rate
Orifice size [mm]
11,500
1.04
7,500
0.83
4,000
0.62
7,500
0.83
16,500
In: 0.46 / Out: 0.83 (2 pcs)
BURNER ORIFICE SIZES AND OUTPUT RATINGS
(Natural Gas 5 in WCP)
Burner Location
BTU Rate
RF
13,000
LF
9,500
RR
5,000
LR
9,500
Center
22,000
NOTE
Orifice markings:
115
115 – Denotes 1.15 mm orifice size opening.
Orifice size [mm]
1.64
1.40
1.01
1.40
In: 0.85 / Out: 1.36 (2 pcs)