Installing a 4-wire conduit
• Aluminum building wire may be used but it must be rated for the correct amperage and voltage to
make the connection. Connect wires according to this Step 4 depending on the number of wires.
• Wire used, location and enclosure of splices, etc., must conform to good wiring practices and local
codes.
1. Loosen the 3 lower terminal screws from the terminal block. Remove the ground screw and
ground plate and retain them.
2. Cut and discard the ground strap. Do not discard any screws.
3. Insert the ground bare wire tip between the range frame and the ground plate (removed earlier)
and secure it in place with the ground screw (removed earlier).
4. Insert the bare wire (white/neutral) tip through the bottom center of the terminal block opening.
5. Insert the two side bare wire tips into the lower left and the lower right terminal block openings.
6. Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs.). Do not over-tighten the
screws since it could damage the wires.
7. Go to step 5 and proceed with the installation.
Ground strap
Ground plate
STEP 5. REPLACING THE ACCESS COVER
Replace the access cover on the range back. To replace the wire cover, insert double projections in the
pockets located below the opening and tighten the screw.
Manual Installation_30 Oven_SECA_DG68-00109F-04_EN+CFR.indb 10
Wire tips
Black
English - 10
Red
Black
Neutral
White
terminal
White
Red
Ground
wire
(Green)
2017-08-10
5:34:44