Operation
Connecting power and testing
1
pump operation
NOTE: When these pumps are installed in a basin with a
sealed cover, switch operation cannot be observed. The sump
cover usually will have a spare that is plugged with a rubber
plug. This plug can be removed and switch operation can be
observed.
Plug the pump power cord plug into a 115V GFCI power
outlet.
Run water into the pump until the pump starts. Ensure the
gate valve in the discharge line is open.
Allow the pump to operate through several on/off cycles.
Care and Cleaning
WARNING: Ensure the pump is disconnected from the
power source before attempting to service or remove any
component.
WARNING: Do not remove the impeller. Removal of the
impeller requires special tools and can only be performed
by an authorized service center.
To clear a pump that is clogged with debris:
Unplug the pump to disconnect the electrical power.
Unscrew the six screws (1) on the volute (2).
Remove the volute (2) and the gasket (3).
Remove debris from around the impeller (4).
Reassemble the pump.
2
Operating the pump
When the float switch (1) moves up over the top of the
pump, the pump begins to operate. When the water lowers
to a certain level, the float switch (1) will turn the pump off.
NOTE: Ensure the pump is submerged in water. Running the
pump dry can damage the pump.