Electrical connecting
The cabinet operates on 230 V/50 Hz.
The wall socket should be easily accessible.
All earthing requirements stipulated by the local electricity authorities must be observed. The
cabinet plug and wall socket should then give correct earthing. If in doubt, contact your local
supplier or authorized electrician.
The flexible cord fitted to this appliance has three cores for use with a 3-pin 13-Amp or 3-pin 15-
Amp plug. If a B.S. 1363 (13-Amp) fused plug is used, it should be fitted with a 13-Amp fuse.
The wires in this mains lead are coloured in accordance with the following code:
Green/Yellow: Earth, Blue: Neutral, Brown: Live.
The main electrical connections must be done by skilled electricians.
Start-up of the cabinet
Before use, we recommend that the cabinet is cleaned, see the section on maintenance and cleaning.
Thermostat
The thermostat is placed in the control panel, see fig. 2.0.
Fig. 2.0
There are models with 1 and 2 thermostats.
Models with 1 thermostat has been pre-set as a freezer, but can be programmed as a cooler.
Models with 2 thermostats has been pre-set as a cooler and a freezer, and are equipped with a
switch for easy change of function.
The control panel contains a service-switch for the compressor which can be used for cleaning.
The light switch should be turned off during nights to save energy.
When turning on the cabinet the display will show the current temperature in the cabinet.