Installation (continued)
11
Installing the shower head
Attach the shower head (C) to the shower arm
(B). Carefully tighten the shower head (C) with
a clean strap wrench.
Adjusting the temperature
1
Removing the handle,
escutcheon, and inverter
Unscrew the set screw (G) from the handle (F), and
then remove the handle (F) from the valve body (D).
Unscrew the escutcheon screws (AA), and
remove the escutcheon (E) from the valve
body (D).
Unscrew the sleeve (1) from the valve body (D).
Unscrew the screw (2) from the inverter (3),
and then remove the inverter (3) from the
valve body (D).
2
Remove the red limit stop ring
Remove the red limit stop ring (1) from the
cartridge assembly (2).
B
C
E
AA
F
G
1
10
D