INSTRUCTION MANUAL FOR DISHWASHERS
Remove the protective film from its body panels before operating the
dishwasher.
The power supply must be fitted with a omnipolar circuit breaker (master power
switch) to break all contacts including neutral, with a contact gap of at least 3
mm and thermal cutout or fuses, which must be set or rated to the power
indicated on the machine's nameplate.
The master power switch must be fitted to the power line in the vicinity of the
installation and may be connected to only one machine at a time.
The mains voltage and frequency must match the nameplate ratings.
The installation must include a grounding system conforming with established
electrical safety legislation, to protect the operator and the appliance itself
Mod.
V~
Hz
kW
A
S/N
H
O
kPa
°C
2
This appliance conforms to EN/IEC 61000-3-11 certification if the system impedance Z
than or equal to Z
max
system. The installer or appliance user is responsible for checking that the appliance is connected
exclusively to a supply with system impedance Z
Utensil washers
Hood
Undercounter
The power cable, which must be exclusively type H07RN-F with current capacity at 60°C on the
cable:
Must not be stretched or crushed during normal operation or routine maintenance.
The appliance must also be connected to an equipotential system, connected by a screw marked
by the symbol 5021 - IEC 60417.
The equipotential cable must have a cross section of 10 mm².
Respect the polarities indicated in the wiring diagram.
For further information, refer to the wiring diagram.
Do not use multi-sockets, adapters, cables of an inadequate cross section or type or
with extensions not conforming to established electrical installation regulations.
in the point of interface between the user's supply system and the public
Three-phase machine
o -5x2.5 mm^2 up to 20 A
o -5x4 mm^2 up to 30 A
o -5x6 mm^2 up to 38 A
o -5x10 mm^2 up to 54 A
Single-phase machines
o -3x1.5 mm^2 up to 16 A
o -3x2.5 mm^2 up to 25 A
MAXIMA - NIJVERHEIDSWEG 23 A/D - 3641 RP MIJDRECHT
THE NETHERLANDS - +31 (0) 297 253 969
WWW.MAXIMA.COM
3.3 Electrical connection
less than or equal to Z
sys
Z
max
0.21 Ω
0.24 Ω
0.41 Ω
-
INFO@MAXIMA.COM
UK
is less
sys
max
Page 5 of 14