Maintenance & Cleaning - BoomToneDJ S-1500Pro DMX Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Maintenance & cleaning
a)
Installing or replacing the lamps
Before replacing the lamps let the lamps cool down, because during operation, the lamps
can reach temperatures of up to 700℃. Wait at least 10 minutes after use before opening the
housing.
During the installation of the lamp do not touch the glass bulb bare handed. Always use a
cloth to handle the lamp during insertion and removal.
Do not install lamps with a higher wattage. They generate higher temperatures than for
which the device was designed for.
For the installation, you need a 1500W strobe tube.
Procedure:
7)
Unscrew the screw
Carefully remove the glass pane and sponge , making sure it doesn't get damaged
8)
9)
Remove the old lamp carefully
10) Place the new lamp
11) Close the glass pane.
12) Fasten the screw
CAUTION: 1. Do not operate this device with open cover!
2. The glass pane has to be replaced when it is damaged!
3. The lamp has to be replaced when it is damaged or deformed!
4. Only install the lamp with the device unplugged from the mains!
b) Replacing the fuse
If the lamp burns out, chances are the internal fuse might too. Only replace the fuse with a
fuse of the same type and rating (see technical specifications at the end of this user
manual).
Since the fuse for this device is an internal fuse, it should only be replaced by your agent or
an authorized dealer.
CAUTION: Only replace the fuse with the device unplugged from the mains!
c) Mounting the device
The installation must always be secured with a secondary safety attachment, e.g. an
appropriate safety cable.
Never stand directly below the device when mounting, removing or servicing the device.
Procedure:
The stroboscope should be installed outside areas where persons may reach it, walk by or
be seated.
9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1500w dmx strobe

Table des Matières