TABLE FOR THE CHOICE OF THE INJECTORS
BE
FR
BURNERS
Auxiliary (A)
Semi-rapid (SR)
Rapid (R)
Triple-ring (TC)
A
IR VENT NECESSARY FOR GAS COMBUSTION
BURNERS
Auxiliary (A)
Semirapid (SR)
Rapid (R)
Triple-ring (TC)
LUBRICATION OF THE GAS TAPS
– In case of difficulty in the gas taps operation, call Service.
IMPORTANT
All intervention regarding installation maintenance of the appliance must be
fulfiled with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this
obligation.
Reduced
Nominal
Power
Power
[kW]
[kW]
1,00
0,30
1,75
0,45
3,00
0,75
3,50
1,50
Air vent necessary [m
G30/G31
28-30/37 mbar
By-pass
Ø injector
[1/100 mm]
[1/100 mm]
27
50
32
65
42
85
65
95
=
3
]
2,00
3,50
6,00
7,00
II
Cat:
2E+ 3+
G 20/G 25
20/25 mbar
Ø injector
By-pass
[1/100 mm]
[1/100 mm]
72 (X)
97 (Z)
115 (Y)
135 (T)
3
(2 m
/h x kW)