PROBLEM SOLVING
When the detector stops working, check the possible failures and the
solutions suggested in the following table that maybe will help you to
solve the problem:
Problem
Lamp does not
light up
Lamp stays
ON
continuously
Lamp is
switched on
and off
cyclically
Nuisance
triggering
Possible cause
1 - Power is not
turned on
2 - Wrong wiring
3 - Incorrect setting
of Lux
4 - Lamp may be
defect
5 - 'Permanent OFF'
set via remote
control
(if used)
6 - Temperature
very high
1 - The time of
disconnection fixed
is too long
2 - Thermal activity
detected withing
detection area
3 - Wrong wiring
4 -
Permanent ON'
'
set via remote
control (if used)
The load
(fluorescence,
contactor,...) is
continuously
generating harmonics
triggering the detector
in each switching
Heat sources, highly
reflective objects or
any object which may
be swayed by the
wind is within the
detection range
Suggested solution
1 - Supply the
detector
2 - Check
connections
3 - Check this setting
4 - Replace lamp
5 - Press OFF key to
return to automatic
mode
6 - Wait for the
reduce the
temperature
temperature and
test the detector
1 - Reduce the time of
disconnection and
verify that the lamps
go out passed the
time
2 - Remove heatsource
(persons, animals,
fans, etc.)
3 - Check connections
4 - Press ON key to
returnto automatic
mode
Separate the detector
from the load or con-
nect a RC harmonic
suppression filter
between L' and N
Avoid aiming the
detector towards any
heat source, any
reflective surface or
swaying objects
Asegúrese que no
hay objetos que se
mueven con el viento.
Reduce the
Sensitivity of the
detector with the
Remote Control
(EM MAN DM0).