5.3. Drainage and storage
Drainage
1
Check the stopper on the bottom of the pool and the drain cap.
2
Unscrew the drain cap.
Connect the drainage hose.
3
Press the drain valve. Completely drain all water from the spa pool.
4
Once empty, the pool can be cleaned with soap and water.
1
2
Storage
5
Press the bubbling button to blow out the water inside the jet holes. Unplug the
pump, remove the filter cartridge from the inner wall of the pool.
Use a towel to wipe off the pool, dry 24 hours.
6
Unscrew the valves to deflate the pool.
7
8
Fold the pool.
It is recommended that store the SPA in its original package in a warm dry place.
5
6
5.4. Repair kit
Little holes or puncture can be repaired with the repair kit included and glue reserved to
pool liner.
1. Find the leak.
2. Thoroughly clean the area surrounding the leak.
3. Cut a piece of repair material in round shape, which should be larger than the dam-
aged area.
4. Apply adhesive to the underneath side of the patch and around the area to be re-
paired.
5. Put the patch on the damaged area and press down firmly. Allow 12 hours for repair
to dry. After patch has dried, apply glue around the edges for a complete seal (dry 4
hours).
14
5. MAINTENANCE
3
7
8
6. TROUBLE SHOOTING
6.1. Troubleshooting
Here are some useful tips to help you to diagnose and rectify common problems.
Reference
Inlet – The inlet is whereh the filter is attached.
Outlet – The water outlet is directly above of the filter and is where the hot water is
recirculated back into the spa from the heater unit.
Problem
Cause
Control panel
screen does not
Check power source
operate
Temperature set is too low
Filter Cartridge is dirty
SPA pump does not
heat properly
Too low water level
Heating element defective
Pump is overheating
Bubble massage
Auto shut-down feature (30min) is
system does not
activated
work
Malfunction of the pump unit
Filter Cartridge is dirty
Water filtration does
Inlet and outlet blocked
not work
Air inside the pump
Malfunction of the pump unit
Adaptor seal improperly
Pump leakage
Water leakage from pump body
Spa spa leakage
Spa spa is torn or punctured
Insufficient filtering time
Filter Cartridge is dirty
Water is not clean
Spa filled water quality
Improper water treatment
After 150 cumulative hours of filtration operations, an audible alarm will sound and the LCD display will
show the characters CHG, followed by FIL, to remind you to change or clean the filter. You can hold
CHG
FIL
the filtering button 5 seconds to turn off the buzzing. The filtering system will turn off, you can press the
button to active the filtering system again.
Solution
Power failure
Reset the GFCI / Check if the wiring system is adapted to the
power of the pump unit.
Call for service if it does not reset
Set to a higher temperature
Clean or Replace the cartridge (see chapter 5.2)
Fill water to minimum water level
Call for service
Cut off the power and wait until the pump has cooled.
Press the bubble button to reactivate
Call for service if it does not reset
Clean or Replace the cartridge (see chapter 5.2)
Clean the inlet and outlet
Fill water to minimum water level
Call for service if it does not reset
Replace the seal in the right position
Check the pump body, call for service
Use provided repair kit (see chapter 5.4)
Increase the filtering time
Clean or Replace the cartridge (see chapter 5.2)
Change the spa water completely
Refer to the chemical manufacturer's instructions
US
15