Store unused equipment in a dry, locked place out of the reach of children.
Note the following to extend the service life of your air dehumidfier and to ensure a perfect function:
Drain the water collecting container and dry it carefully.
Clean the filter.
Thoroughly clean the device.
Check the air dehumidifier for perfect condition to ensure a safe use of it after a longer period of storage.
Carefully cover the air dehumidifier.
Power off the device and disconnect the mains plug before each troubleshooting.
Fault
Motor does not start
Only little condensation or no water Room temperature or humidity of air out
Device shuts down in continuous
operation with drain hose
Water flows out of the device
Unusual noise or vibrations.
Please contact the manufacturer or the customer service if you cannot eliminate a fault although you have carried out all
functional tests.
Immediately put the device out of operation if it does not function properly.
S
t
o
S
t
o
P
o
s
s
i
b
P
o
s
s
i
b
Possible cause
No power supply.
Mains cable defective.
Water collecting container full.
Humidity of the room air lower than the
set value.
of the working range.
Air filter contaminated.
Air supply or exhaust air outlet blocked.
a) Interior of the device heavily
contaminated.
b) Refrigerant circuit defective.
Doors and/or windows open.
a) Drain hose kinked or wound up.
b) Not enough descending gradient.
Water frozen in the hose.
Leakage
of
the
water
container.
Device is placed on an uneven floor.
Screws, nuts or other parts loosened.
r
a
g
e
r
a
g
e
l
e
f
a
u
l
t
s
l
e
f
a
u
l
t
s
Corrective action
Check fuses.
Have it checked (electrician).
Drain the water collecting container.
Check the set humidity value and set another value
if required.
a) Check the room temperature (5 °C to 32 °C).
b) Check the humidity of air (at least 30% RH).
c) Check the set humidity value and set another
value if required.
Clean
the
Maintenance").
Check. Place the device on another location of
required (adhere to the minimum distance to walls
(10 cm)).
Contact the manufacturer or customer service.
Close doors and/or windows.
Re-route the drain hose to allow the water to flow
out unhindered.
Take precautions to avoid water freezing.
collecting
a) Check the water collecting container.
b) Replace the water collecting container.
Place the device on an even floor.
Tighten the parts.
If the parts cannot be tightened, are in the interior
of the device or the noise persists: Contact the
manufacturer or the responsible customer service
respectively
air
filter
(see
"Cleaning
and
19