Read all instructions before using or installing this product.
Symbols and their meaning
Caution! Warning of personal injury or material
damage
Caution! Warning of electric shock.
Caution! Warning of water damage.
Note, tip or reference
Correct assembly/functional test
Incorrect assembly
Observe assembly details
Optional/accessories
Button on/off
Lighting above
Lighting below
Light colour - daylight white (cool white)
Light colour warm white
Technical data
– Supply voltage:
– Required electrical outlet:
– Max. power consumption:
Prod. No.:
80020006EG05X00
80020007EG05X00
80020008EG05X00:
80020009EG05X00:
80020010EG05X00:
80020011EG05X00:
80020012EG05X00:
– Maximal load each shelf:
– Maximal load mirror cabinet total:
- 800200060G05X00:
- 800200061G05X00:
- 800200070G05X00:
- 800200071G05X00:
- 800200080G05X00:
- 800200081G05X00:
- 800200090G05X00:
- 800200091G05X00:
- 800200100G05X00:
- 800200101G05X00:
- 800200110G05X00:
- 800200111G05X00:
- 800200120G05X00:
- 800200121G05X00:
Switch on/off
120V AC 50Hz/60Hz
15 A / 1800 W
Width
Light
23-5/8" (600)
27.8 W
27-9/16" (700)
32.3 W
31-1/2" (800)
35.3 W
35-7/16" (900)
36.8 W
39-3/8" (1000)
42.1 W
43-5/16" (1100)
43.6 W
47-1/4" (1200)
48.1 W
max 3.3 lb
58.2 / 63.7 lb
71.4 / 78.3 lb
66.1 / 72.8 lb
81.1 / 89.1 lb
74.3 / 81.6 lb
90.8 / 99,9 lb
82.2 / 90.6 lb
100.5 / 110.7 lb
90.4 / 99.4 lb
110.2 / 121.5 lb
98.3 / 108.5 lb
119.9 / 132.3 lb
106.5 / 117.5 lb
129.4 / 143.1 lb
– Degree of protection:
– Ambient conditions:
- Operating temperature
- Storage temperature
– Luminous color
Mounting dimensions, see page 11.
Operation
As with a multiway switch, the mirror cabinet
can be operated with either button A, the sensor
button B on the mirror, or with an external light
switch C (installation type I or III); refer to fi gure
3 on page 12.
Depending on the type of connection, the
sockets are permanently supplied with voltage
(I or II) or switch controlled (III).
KEUCO recommends connection type I in
combination with a switch for switching on/off .
B
Before installation check whether the fastening materials
included are suitable for the anchoring base. The fas-
tening materials are suitable exclusively for stud walls
with timber constructions or for drywall constructions with
timber wood reinforcement.
Installation, see fi gure 1 onwards on page 12.
• Check the mounting position, see fi gure 1.
• Remove the door, see fi gure 2.
• Connect the mirror cabinet to the power supply,
see fi gure 3.
• Place the mirror cabinet in the installation opening,
see fi gure 4 on page 13.
• Fix the mirror cabinet in the installation opening
with the screws, see fi gure 5.
US
NEMA 1
32° – 113° F
-40° – 158° F
2700 – 6500 Kelvin
C
A
L
= BLACK
N
= WHITE
PE
= GREEN
L1
= RED
3