This Conversion should only be performed by a Qualified Service Technician or Licensed Plumber
1.
MAKE SURE THAT THE GAS SUPPLY TO THE FIRE PIT (AND ANY NEARBY ELECTRICAL
SOURCES/APPLIANCES) ARE SHUT OFF.
2.
Carefully detach the flex line connector hose attached to the orifice holder (Figure # 1) and unscrew the orifice holder
from the burner pipe (Figures #1 and # 2).
3.
Remove the orifice from the holder (Figure # 2 ) and replace it with the proper sized one for your gas requirement.
Propane requires the smaller orifice.
4.
If you are converting from propane (LP) gas to natural gas, install the air shutter sleeve so that the air intake holes are
closed (Figure #2). For Propane gas, remove the air shutter so that the air intake holes are open (Figure #1). After the
unit is assembled for use, it is required a "leak check" by using liquid soap solution on all connections are before placing
the unit in operation.
5.
IT IS NECESSARY TO ATTACH THE LABEL OR RATING PLATE INCLUDED WITH THE CONVERSION KIT TO
CLEARLY INDICATE THE FIELD CONVERSION.
Burner
Orifice
Air Intake hole open for LP Gas
Burner
Orifice
When converting to natural gas, the air shutter
sleeve MUST be installed over the burner pipe.
MANUFACTURER'S USE ONLY - QUALITY CHECK
Orifice # (Main)
Orifice # (OTHER)
Leak Test
Burn Test
Gas Type
CONVERTING YOUR FIRE PIT TO NATURAL GAS
FIGURE 1
Orifice Holder
FIGURE 2
Orifice Holder
#42
#13 / COM0568CK
LP - NAT
Flex Line
Connector Hose
Follow steps 1 – 5 shown above.
THE CONVERSION MUST BE CARRIED OUT BY
A QUALIFIED SERVICE AGENCY, IN
ACCORDANCE WITH THE REQUIREMENTS OF
THE MANUFACTURER, PROVINCIAL OR
TERRITORIAL AUTHORITIES HAVING
JURISDICTION AND IN ACCORDANCE WITH
THE REQUIREMENTS OF THE CAN/CGA-B149.1
OR CAN/CGA-B149.2
INSTALLATION CODES.
Flex Line
After conversion follow Operating Instructions
Connector Hose
found on Page 11.
After The Unit Is Converted, it Must Be Tested
to Verify the Inlet and Manifold pressures are
as specified on Page 3. Additionally, the
qualified service agency must verify that the
input rate of the converted appliance match
the rate listed below.
Work Order #
BTU Rating
Serial #
Model #
Air Shutter Sleeve
Inspector:
Page 14
Casual Fireside Fire Pits Are
Suitable For Installation from
0 - 4,500 ft. Without Modification.
Date
LP 65,000 / NG 65,000
COM0568
X