(within 5 seconds). Leds flashing 6 times in-
dicate the procedure is completed.
WARNING! This operation deletes perma-
nently the preset codes.
Emergency button:
In the event that the radio control does not
work, use the emergency button to switch
the appliance off. After any necessary repairs
have been performed, reset the emergency
button.
WARNIING
The battery should be replaced every year
to guarantee the optimal range of the
transmitter.
To replace the exhausted battery, take
the plastic lid off, remove the battery and
replace it with a new one, observing the
correct battery polarities.
Used batteries should be discarded in
special collection bins.
The below product:
RC001 Radiio Controll
complies with the specifications set out in
the R&TTE Directive 99/5/EC.
WARNING
Any adjustments or modifications which
have not been expressly approved by the
holder of the legal conformity certificate
may invalidate the user's rights relating to
the operation of the device.
The products are endowed with an electronic
device which allows the automatic switching
off after 4 hours working from the last ope-
ration.
Rev. 0 26/08/14
17
TIMING
As a result of the new EU65 "Energy label" and
EU66 " Ecodesign" regulations issued by the
European Commission, which came into force
as from January 1st, 2015 , our products have
been adapted to comply with these new re-
quirements.
All of the models complying with the energy
label requirements, are equipped with new
electronics including a timer device for suc-
tion speeds control, when the air capacity ex-
ceeds 650m³/h.
Internal motor models, with maximum air
capacity higher than 650m³/h, are equip-
ped with a timer device that automatically
switches the suction speed from 4th to 3rd
speed, after 5 minutes operation.
External motor models are equipped with re-
mote motors that , as for internal motor ver-
sions, include a timer device that switches
down the suction speed when it exceeds 650
mᵌ/h. (See External Motors Instructions ).
Remote motors, whose air capacity exce-
eds 650m³/h at both 4th and 3rd speed, will
have the following by default timer control
functions: The suction speed is automatical-
ly switched from 4th to 2nd speed, after 6
minutes operation.
If the appliance is working at 3rd speed, it
is automatically switched to 2nd speed, after
7 minutes operation. Operation speeds can
also be changed during operation.
The energy consumption of the appliance in
stand – by mode is lower than 0.5W.