Elpro S50-T1.EFO
GB
Accessory
24 V - 3 W max.
Light indicating
bollard in motion :
24 Vdc output:
Motors:
Limit switches:
External
flasher:
Signalling LED lights:
Beeper, post in motion:
Board power supply:
ANTI-TERRORISM RETRACTABLE BOLLARDS
Electrical connections
Light on = post down, gateway cleared
3
8
Light off = post up, gateway closed
Flashing 0,5 s (fast) = post moving up
Flashing 1 s (normal) = post moving down
With an external time clock: 2 short flashes
followed by a longer pause
+
-
Output for any possible 24 Vdc application
55 56
200 mA for the accessories
Important: if the bollard does not operate in
16 17 18
phase with the open/close commands as
required, swap connections to 17/18.
M1
Bollard 1
MOTOR 1
11
12
It is possible to connect an external flashing
lamp to the bollard in addition to the
51 52 53
incorporated LED lights. The flasher will be
on
during
movements and during the dwell time (if
pre-selected)
230 V - 100 W max
Output for the LED lights that are always on
51 52 53
blinking during the rising and lowering
movements of the post and with the post in
standing position. They go off with post in
down position.
The acoustic device is inside the post and is
on only during the rising and lowering
51 52 53
movements of the post.
Elpro S50-T1.EFO
board and PC controller
power supply
BOARD POWER SUPPLY
230 V ± 10%
F N
50 Hz SINGLE-PHASE
CONTROLLER FOR TALOS M50
55
56
the
rising
and
lowering
10
Dip-switches and LED status of the various functions
DIP-SWITCH N° 12:
ON: Motor run time max. 90 s
12
OFF: Motor run time max. 18 s
T1
MOTOR RUN TIME
DWELL TIME
1 s - 22 s
L8 ON = it goes off with post 1 down
L9 ON = it goes off with post 1 up
L10 ON = it goes off with post 2 down
L11 ON = it goes off with post 2 up
L12 ON = it goes off with post 3 down
L13 ON = it goes off with post 3 up
DIP-SWITCH N° 4:
ON: Pre-flashing
4
OFF: No pre-flashing
DIP-SWITCH N° 10:
ON: Flasher. Deactivated during dwell time,
automatic mode
10
OFF: Flasher. Activated during dwell time,
automatic mode
T2