Contact 1.800.762.1142 for assistance. Do not return to place of purchase.
Installing LP Gas Tank
To operate you will need (1) precision-filled standard grill LP gas
tank (20#) with external valve threads.
Note: An empty standard grill LP gas tank weighs approximately
18 lbs. A precision-filled standard grill LP gas tank should weigh
no more than 38 lbs.
Insert LP Gas Tank
Place precision filled LP gas tank upright into hole in grill body so the tank valve is facing the
gas line connection.
Secure LP Gas Tank
Turn wing nut clockwise untill tight.
Connect LP Gas Tank
Before connecting, be sure that there is no debris caught in
the head of the LP gas tank, head of the regulator valve or
in the head of the burner and burner ports.
Connect gas line to tank by turning knob clockwise until it
stops.
Disconnect LP Gas Tank
Before disconnecting make sure the LP gas tank valve is
"CLOSED".
Disconnect gas line from LP gas tank by turning knob
counterclockwise until it is loose.
Need a tank of gas? Try tank exchange service. It's easy, fast, safe,
and available at tens of thousands of conveniently located retail outlets
nationwide. You can purchase a new full tank or exchange your empty for
a precision filled one.
All manuals and user guides at all-guides.com
Operating Instructions
Checking for Leaks
Burner Connections
1. Make sure the regulator valve and hose connections
are securely fastened to the burner and the tank.
If your unit was assembled for you, visually check
the connection between the burner venturi pipe and
orifice. Make sure the burner venturi pipe fits over
the orifice.
WARNING: Failure to inspect this
connection or follow these instructions
could cause a fire or an explosion
which can cause death, serious bodily
injury, or damage to property.
2. Please refer to diagram for proper installation.
(Figure 1 and 2)
3. If the burner pipe does not rest flush to the orifice,
please contact 1.800.762.1142 for assistance.
Tank/Gas Line Connection
1. Make 2-3 oz. of leak solution by mixing one part
liquid dishwashing soap with three parts water.
2. Make sure control knobs are "OFF". (Figure 3)
3. Turn LP gas tank valve to "OPEN".
4. Spoon leak check solution at all "X" locations
(Figure 4)
a. If any bubbles appear turn LP gas tank valve to
"CLOSED", reconnect and re-test.
b. If you continue to see bubbles after several
attempts, turn LP gas tank valve to "CLOSED"
and disconnect LP gas tank and contact
1.800.762.1142 for assistance.
c. If no bubbles appear after one minute turn LP gas
tank valve to "CLOSED", wipe away solution and
proceed.
Operating Main Burners
First Use
1. Make sure all labels, packaging and protective films
have been removed from the grill.
2. Remove manufacturing oils before cooking on this
grill for the first time by operating the grill for at
least 15 minutes on "HIGH" with the lid closed. This
will "heat clean" the internal parts and dissipate
odors.
Lighting
1. Open lid. Attempting to light the burner with the
lid closed may cause an explosion!
2. Make sure there are no obstructions of airflow to
the burners. Spiders and insects can nest within
and clog the burner / venturi tube at the orifice. A
clogged burner tube can lead to a fire beneath the
appliance.
3. All control knobs must be in the "OFF" position.
(Figure 3)
4. Turn LP gas tank valve to "OPEN".
5. Select burner to light. Push and turn control knob
counterclockwise to "HIGH".
6. Press the electronic igniter button and hold for 5
seconds to light burner.
7. If ignition does not occur in 5 seconds, turn burner
control knob "OFF", wait 5 minutes, and repeat
lighting procedure.
8. If igniter does not light burner, use a lit match
secured with the lighting rod provided to light
burners manually. Access the burners through the
cooking grid and heat plates. Position the lit match
near side of the burner. (Figure 5)
Important: Always use the lighting rod provided when
lighting burners with a match.
9. After lighting, observe the burner flame, make sure
all burner ports are lit and flame height matches
illustration. (Figure 6)
Note: Each burner lights independently - repeat steps
5-9 for the other burners.
page no.
9
Figure 1
Burner
Valve Soft Pipe
venturi pipe
Connection
LP Gas
Valve with
Main Burners
Orifice
Figure 2
LP Gas Valve
LP Gas
with Orifice
Connection
Valve
Soft Pipe
Burner
Connection
Side Burner
venturi
pipe
Figure 3
Figure 4
X
X
X
X
X
Figure 5
Figure 6
Slight
Flame
Yellow
Slight
Blue
Burner
Dark
Blue