WARNING Before using this outdoor fire table, make
sure you have read, understand and are following all
information provided in the Important Safety Information
section of this manual. Failure to follow those instructions
can cause death, serious injury or property damage.
Prior to each gas fire table operation, check the hose and
valve for evidence of excessive abrasion or wear through
the visual check hole on the side of the base. Replace
visual check cap prior to operating fire table.
BURNER CONNECTIONS
Make sure the Natural Gas hose and quick disconnect
socket connections are securely fastened to the burner
and the gas supply. If your unit was assembled for you,
visually check the connection between the burner pipe
and orifice. Make sure the burner pipe fits over the
orifice.
!
Warning: Failure to inspect this connection or follow
these instructions could cause a fire or an explosion,
which can cause death, serious bodily injury, or damage
to property.
Please refer to diagram for proper installation.
If the burner pipe does not rest flush to the orifice please
contact Real Flame at 1-800-654-1704 for assistance.
CHECKING FOR LEAKS
Make a leak check solution by mixing 1 part dishwashing
soap with 3 parts water in a spray bottle.
Ma
ke sure control knob is "OFF." Then, turn Natural Gas
on at its source.
Spray leak solution on valve connections paying particular
attention to the areas indicated by arrows.
If an
re-test. If you continue to see bubbles after
several attempts, disconnect Natural Gas source and
contact Real Flame® at 1-800-654-1704 for assistance.
If no bubbles appear after one minute turn source OFF,
wipe away solution and proceed.
12
Burner Pipe
, reconnect and
Pre-Use Instructions
Visual check hole location
Check for leaks at these locations
8