Instructions for use (rev 120121)
4.3. CURATING TREATMENT
To provide a maximum decontamination of the room, it is strongly advises for the first usage, to proceed to
a complete curative treatment. For this operation, we advise to set the volume selector (f) to 450m
minutes (for a room's volume limited to 100m
4.4. PREVENTIVE TREATMENT
Set the volume selector (f) on the estimated room's volume to be treated (in m
5. MAINTENANCE
Before to carry out the maintenance work and/or cleaning: disconnect from the main
power supply (switch OFF and unplug to mains socket).
Observe the following recommendations to ensure the longevity of the device:
- Do not use abrasive, solvents or flammables products for cleaning (outside and inside).
- Clean the machine outside with a soft, dry cloth.
- Make a visual inspection of the nozzle's connection hoses with the tank (n° 26) and with the compressor
(n° 29). If damaged: do not use the equipment before replacing the defective part(s).
- The air dry compressor (without oil) does not require any particular care.
- The nozzle is a very important part of this equipment. The length of the spray must be at least of 1m to
1,50m. In case of problems, the nozzle must be cleaned: nozzle's maintenance.
NOZZLE'S MAINTENANCE – steps
- The key for nozzle provided (d) allows the fast taking
apart,
- Make a ¼ of a turn (counter clock wise) with the key for
nozzle (n° 4),
- Take off the nozzle's insert (n° 3) and central part (n° 2),
- Let it soak nozzle's insert (n° 3) and central part (n° 2)
during 2 hours in bleach, then rinse thoroughly with
clean water,
- Proceed in reverse order for assembly.
If the failure persist, contact the after-sale service.
Nozzle's replacement may be necessary.
UGIN DENTAIRE
3
).
3
).
Figure 1: nozzle's maintenance
ASEPTOJET S
3
/ 30
16