Télécharger Imprimer la page

Safety first PS610 Manuel D'utilisation page 33

Publicité

Les langues disponibles

Les langues disponibles

User manual electronic lock
3. Opening delay and opening window
Opening delay 1-99 minutes:
The waiting time before you can open the lock.
Opening window 1-9 minutes:
You have to enter the code again to open the safe during this window (the period in which you can open it)
3.1 Programming opening delay and opening window
You can only program an opening delay and window by using the master code.
Make sure that the safe door is open when you start programming an opening delay and window
(ON – master code – ENTER)
Step
Press ON
1.
Press Enter
2.
Press 6
3.
Press Enter
4.
Key in the master code, e.g. 567891
5.
Press Enter
6.
Enter the opening delay using two digits,
7.
e.g. 5 minutes
Enter the opening window using single digit,
8.
e.g. 1 minute
Press Enter
9.
The opening delay and the opening window are now set.
Key in code - start opening delay
Waiting time opening delay
Opening window - re-enter your code
Action
Key
ON
Enter
6
Enter
567891
Enter
05
1
Enter
Signal