ELECTRICAL CONNECTION
• The installation of this appliance and the connection to the electrical network should be
entrusted only to an electrician perfectly to the fact of the normative regulations and which
respects them scrupulously.
• Protection against the parts under tension must be ensured after the building-in.
• The data of connection necessary are on the stickers place on the hob casing near the
connection box.
• The connection to the main must be made using an earthed plug or via an omnipolar
circuit breaking device with a contact opening of at least 3 mm.
• The electrical circuit must be separated from the network by adapted devices, for example:
circuit breakers, fuses or contactors.
• If the appliance is not fitted with an accessible plug, disconnecting means must be
incorporated in the fixed installation, in accordance with the installation regulations.
• The power cable must be placed so that it does not touch hot parts of the hob.
Caution !
This appliance has only to be connected to a network 220-240 V~ 50/60 Hz
Connect always the earth wire.
Respect the connection diagram.
Use the connecting cable that is attached to the device.
The green / yellow wire correspond to the earth wire, the blue wire correspond neutral wire and
the brown wire correspond to the phase.
Mains
220-240V~
50/60Hz
400V~ 50/60Hz
Connection of the hob
For the various kinds of connection, use the brass bridges which are in the box next the terminal
Monophase 220-240V~1P+N
st
Put the 1
bridge between terminal 1 and 2
Attach the earth to the terminate "earth", the neutral N to terminal 4, the Phase L to one of the
terminals 1 or 2.
Biphase
400V~2P+N
Attach the earth to the terminate "earth", the neutral N to terminal 4, the Phase L1 to the
terminals 1 and the Phase L2 to the terminal 2.
Caution! Ensure that you correctly attach the wires and the bridges and tighten the screws
properly.
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
Connection
Supply cord
1 Phase + N
3 x 2,5 mm²
2 Phases + N
4 x 1.5 mm²
equipped with a faulty earth connection.
Supply cord
H 05 VV - F
H 05 RR - F
H 05 VV - F
H 05 RR - F
18
Circuit braker
25 A *
16 A *