Télécharger Imprimer la page

schmersal AZ 16 ZVK-M16-1637 Instructions Pour Fonctionnement Et Montage page 6

Publicité

Mechanical life, minimum
Positive break travel
Positive break force per NC contact, minimum
Positive break force, minimum
Actuating speed, maximum
Mounting
Type of the fixing screws
Données mécaniques – technique de connexion
Cable entry
Termination
Cable section, minimum
Cable section, maximum
Note (Cable section)
Allowed type of cable
Données mécaniques - Dimensions
Length of sensor
Width of sensor
Height of sensor
Conditions ambiantes
Degree of protection
Ambient temperature
Storage and transport temperature, minimum
Storage and transport temperature, maximum
Permissible installation altitude above sea level, maximum
Conditions ambiantes - Valeur d'isolation
Rated insulation voltage U
i
Rated impulse withstand voltage U
Overvoltage category
imp
1 000 000 Operations
8 mm
10 N
10 N
2 m/s
Vis
2x M6
3 x M16 x 1,5
Bornes à vis
0,25 mm²
2,5 mm²
Toutes les indications relatives à la section du câble sont embouts
compris.
solid single-wire
solid multi-wire
flexible
30 mm
52 mm
90 mm
IP67
-30 ... +80 °C
-40 °C
+85 °C
2 000 m
500 V
6 kV
III
6-11