GB
Type A anchor device in accordance with DIN EN 795:2012 and DIN CEN/TS16415:2017 for attaching personal
protective equipment against falls from a height.
for fastening in reinforced concrete
Before installing the SEKURANT® X20 / X50 props, the load-bearing capacity of the roof structure must be checked. The
technical building regulations must be complied with. At the head of the SEKURANT® X20 / X50 props, loads of up to 8kN
(depending on the design) can occur.
Attention!
The SEKURANT® X20 / X50 prop must not be used as a transport eye or for slinging loads. Only original parts of the
SEKURANT® X system may be used. Assembly may only be carried out by qualified personnel. These assembly instructions
and the SKYLOTEC safety instructions must be read and understood.
In accordance with DGUV 201-056 and DIN EN 795, 10/2012, installation documentation must be prepared. For this purpose,
each installed SEKURANT® X20 / X50 prop must be given a consecutive number and documented photographically before
the roof structure is installed. The photos must be clearly assignable to the anchor point. In particular, the professional
execution of the attachment must be recognisable. The complete documentation must be handed over to the building owner
at the time of the building inspection. It is part of the building inspection and the subsequent regular inspection by an expert.
Our APP (http://www.app.secupohl.com or in the APP store) is a useful tool for this purpose.
Assembly
When used with the SEKU® rope (synthetic fibre rope): min. 2.5 m from the edge of the structure / max. 7.5 m distance
between supports.
When used with the SEKURANT® VARIO rope system: max. 10 m distance between supports.
1.
Position the SEKURANT® X support with base plate on
the ground and mark all four fixing holes. Put the support
aside.
2.
Drill holes with a concrete drill (Ø= 8 mm), perpendicular
to the concrete surface, at least 50 mm deep into the
concrete.
3.
Clean the borehole thoroughly!
4.
Insert 4 pcs. special anchor bolts, the anchor bolt must
be anchored at least 45mm into the concrete.
5.
Put on the SEKURANT® X support and fix it with the
pull-off nuts.
• The correct tightening torque of the dowels
is reached when the hexagon head of the
break-off nut breaks off.
• No torque spanner is required!
6.
Connect the roof layer package in accordance with the
professional rules
7.
Install SEKURANT® X20 / X50 components according
to separate installation instructions.
Requirements
• Concrete quality class:
• Concrete thickness:
• Edge distance:
4
MAT-MA-0061-00_DE_EN_IT_FR_ES_NE.indd 4
MAT-MA-0061-00_DE_EN_IT_FR_ES_NE.indd 4
min. C20/25
min. 100mm
min. 50mm
27.04.2023 08:20:17
27.04.2023 08:20:17