1.6 LEAKAGE CURRENT
3.5mA max.
1.7 POWER FACTOR
PF > 0.95 at 230Vac input and full load
1.8 ErP REQUIREMENT
Meet ErP 2010 requirement (Standard)
2. OUTPUT:
Voltage
*①Max load
Min load
Peak load
*①Combined power
*③Regulation
*②Ripple & Noise
*① The continuous total output power is 650W max.
• The combined power of +5V and +3.3V is 120W max.
• Peak currents may last up to 12 seconds with not more than one occurrence per minute.
*②Add 0.1uF and 10uF capacitors across output terminal during ripple & noise test.
*③ LOAD REGULATION TEST TABLE:
LOAD1
LOAD2
LOAD3
LOAD4
LOAD5
LOAD6
LOAD7
LOAD8
2.1 REMOTE ON/OFF
TTL High/PS-OFF; TTL Low/PS-ON
VIL=0.8Vmax, IIL=-1.6mAmax @Vin=0.4V
VIH=2.0Vmin @Iin=-200uA, VIH=5.25Vmax @open ckt.
+5V
20.0A
0.5A
--
120W
+5,-5%
+5,-5%
50mV
+5V
+12V
0.5A
1.0A
6.0A
1.0A
11.0A
7.0A
20.0A
24.0A
11.0A
26.0A
6.5A
46.0A
8.5A
50.0A
0.5A
2.0A
+3.3V
+12V
20.0A
50.0A
0.3A
1.0A
--
--
--
+5,-5%
50mV
120mV
+3.3V
0.3A
6.0A
10.0A
6.0A
20.0A
10.0A
0.3A
0.3A
-12V
+5Vsb
0.3A
2.5A
0.0A
0.0A
--
3.0A
--
--
+10,-10%
+5,-5%
120mV
50mV
-12V
+5Vsb
0.0A
0.0A
0.0A
0.1A
0.1A
0.5A
0.2A
1.0A
0.2A
1.5A
0.3A
2.5A
0.3A
0.5A
0.0A
0.0A
02