SPECIFIC WARNINGS FOR MODELS WFSD246LED, WFSD366LED, and WSFD486LED
WARNING –
Risk of Electrical Shock, Opening the LED light section will increase risk for electrocution and could
result in injury or death. To reduce the risk of electric shock, do not open the LED light section. The light has no user
serviceable parts inside.
WARNING
Risk of Electric Shock . The electrical equipment must be connected only to a supply circuit that is
protected by a ground-fault circuit-interrupter (GFCI). Such a GFCI should be provided by the installer and should be
tested on a routine basis. To test the GFCI, push the test button. The GFCI should interrupt power. Push reset
button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI
interrupts power to the electrical equipment without the test button being pushed, a ground current is flowing,
indicating the possibility of an electrical shock. Do not use this electrical equipment. Disconnect the electrical
equipment and have the problem corrected by a qualified professional before using.
WARNING –
Risk of Electrical Shock
will increase risk for electrocution and could result in injury or death. To reduce the risk of electric shock, do not use
anything other than the OEM transformer.
WARNING –
Risk of Electrical Shock
result in injury or death. Do Not use extension cords on this unit.
INSTALLATION INSTRUCTIONS:
Read through the instructions entirely, before beginning installation.
NOTICE: This waterfall unit, including the electrical components, includes no serviceable parts. In the event of a
product failure, the entire unit must be removed and replaced.
IMPORTANT: Lay waterfall on flat surface in the original packaging until ready to install. Do not remove grout guard until
the installation is complete. This guard will protect the waterfall opening from damage. Protect the unit from direct
sunlight until unit is installed.
See the chart below for the approximate projection of the waterfall. Use this chart in planning the layout of your waterfall.
Prior to placement of waterfall, ensure that the orientation of the waterfall is
correct. Do not point lip downwards. Refer to Figure below.
Create cement mortar bed in the bottom of the notch as a base for the
waterfall. Set the waterfall in the bed while maintaining a minimum of 25
mm extending beyond the unfinished pool wall. Note: lip must extend a
minimum of 10mm beyond the finished pool wall. Press into place and
level.
Apply a minimum of 12mm of cement mortar to the top and sides of the
waterfall. Remove any excess cement on the pool side of the waterfall.
Remove bender board after installing coping.
After final installation, including all plastering, remove the grout guard.
,
Use of any transformer other than the original model supplied with this unit
,
Use of any extension cord will increase risk for electrocution and could
PREPARATION AND BOND BEAM NOTCHING:
FOR CONCRETE INSTALLATIONS: During the rebar installation, allow an
offset of 100mm below the top of the frame that extends the length plus
50mm of the waterfall.
Notch the beam 100mm below the top surface for the width plus 25mm
of the waterfall.
FOR VINYL/FIBERGLASS INSTALLATIONS: Construct block to allow 100mm
below the top surface for the width plus 25mm of the waterfall.
WATERFALL INSTALLATION:
Use bender board, or
similar material, to
create a level surface to
rest the lip on. Tack
bender board in place
approximately 16mm
below the coping.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS