Installing the Appliance
WARNING:
The following conditions are required for proper installation:
1
Ambient termperature range:
and sources of heat. A maximum ambient temperature of 140º F (60º C) is recommended.
2
Route cables away from power lines, fluorescent lighting fixtures, and sources of noise such as radios,
transmitters, and broadband amplifiers.
3
Ensure that no water or excessive moisture can enter the unit.
4
Allow unrestricted airflow around the unit. A minimum of 1 inch (25.44mm) clearance is recommended.
5
Consideration must be given to the connection of the equipment to the supply circuit and that the
effect of overloading the circuits has minimal impact on overcurrent protection and supply wiring.
Appropriate consideration of equipment nameplate ratings must be used when addressing this concern.
6
This equipment is not intended for use at workplaces with visual display units, in accordance with §2 of
the German ordinance for workplaces with visual display units. To avoid incommoding reflections at
visual display workplaces, this device must not be placed in the direct field of view.
7
This product is not intended to be installed and used in a home or public area accessible to the general
population. When installed in schools, this equipment must be installed in a secure location accessible
only by trained personnel.
Approved Alternate Antennas
Alternate antennas used with the SonicWave 231o must be approved and certified before use. However, in
order to comply with the local laws and regulations, an approval might be required by the local regulatory
authorities.
The included antennas have been tested and approved for use with the SonicWave 231o model.
To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that
the equivalent isotropically radiated power (e.i.r.p) is not more than that required for successful
communication.
Contact SonicWall for a list of antennas approved for use with the SonicWave 231o.
RF Safety Distance
The antennas used for this transmitter must be installed to provide a separation distance of at least 40 cm
from all persons and must not be co-located or operating in conjunction with another antenna or transmitter.
Professional Installation Notice
To comply with FCC part 15 rules in the United States, the SonicWave 231o must be professionally installed to
ensure compliance with the Part 15 certification. It is the responsibility of the operator and professional
installer to ensure that only certified systems are deployed in the United States. The use of the system in any
other combination (such as co-located antennas transmitting the same information) is expressly forbidden.
-30
C – 60
C (-22
F – 140
F).
°
°
°
°
Mount in a location away from direct sunlight
SonicWall SonicWave 231o
Safety and Regulatory Information
8