GASPO 254
- semiautomatic - with gas springs - with 2 x single-phase electric power sockets
230 V
230 V
NO
BOLLARD FITTING INTO THE HOUSING
To facilitate the fitting operations into the
ground housing cylinder, first make the bollard
spring to standing out position. Then sink the
assembly into the ground housing cylinder and
fixing it by the M10x20 TSEI SS steel screws.
6338
GB
Drwg. No.
GASPO 254 FUNCTIONING
Bollard springing up:
- make sure there is no voltage on Gaspo 254
- insert the spanner and turn anticlockwise
- the bollard rises on its own to 500 mm of height, then a "click" sound confirms it is securely
locked; with the bollard in fully standing position, the two single-phase sockets (GEWISS GW
62 426) are made available for use.
- supply the installation with voltage
1
3x2,5 electric cable
inside the bollard
Bringing the bollard to down position:
and pre-wired to
- disconnect Gaspo 254 from the electric power
the sockets
- to lower the bollard into the housing cylinder turn the spanner anticlockwise; in this way
the retaining cog is unlocked
L = 2,5 m
- push the bollard down until it is flat with the ground level and a "click" sound confirms it is
locked in that position by the security cog
- keep the installation without voltage supply
1
2
230 V
NO
2
230 V
NO
INSTRUCTIONS GASPO 254
Single-phase
socket
230 V
Single-phase
socket
230 V
Insulation joint to extend the
inner electric cable on to the
outer cable. Make sure the gel
has come out and is spread all
around the electric cables.
3
4
"click"
3
4
"click"
230 V
230 V
NO