Every configuration parameter featuring preset settings is identified on the
display by an index and a writing. To change parameter values use keys ▲ [key
1] and ▼ [key 2]; use key ► [key 4] to move across parameters.
To go back to the initial page of the programming menu, press the ENTER key
[key 5] which will save changes.
If no key is pressed within 3 minutes, the chronothermostat will quit the
configuration program and will resume the operating mode being used
previously, without saving changed settings.
To cancel changed settings and to reset preset configuration parameter values,
keep keys ▲ [key 1] and ▼ [key 2] pressed simultaneously for about 4 seconds.
ENGLISH
Index
Parameter
1
Type of connected card
2
Temperature scale
3
Type of regulation
3A
Thermal differential
3A
Regulation band
3B
Regulation period
4
Separate temperature probe
configuration
4A
Floor temperature limit
5
Ambient temperature
correction
6
Optimization
6A
Max. optimization duration
(hours)
7
Pump anti-seizure
8
Low battery
9
Baud
10
Software release
42
Writing
Values
COn
rEL / rAd / ---
CELS o
°C / °F
FHAr
Std o
Std / ProP
ProP
DIFF
HI / LO
BAnd
1 °C – 4 °C (step 0.1°C)
Per
5 / 10 / 20 minutes
Sect
--- / FLO / In /Out
Tflo
15 °C – 45 °C
Corr
-4.0 °C to +4.0 °C
Opt
ON/OFF
OPtH
1h – 5h
Pu
ON/OFF
bAtt
--- / On / OFF
baud
0/1
SOFt
xxx
Preset value
none
°C
Std
LO
2 °C
10 minutes
---
27.0 °C
0.0 °C
OFF
2h
OFF
OFF
0
xxx