"Automatic" operating mode
With the "Automatic" operating mode, the chronothermostat adjusts the
operation of the heating or cooling system by following the profiles defined
for the various days of the week. To select "Automatic", press AUTO.
The three temperature levels used can be modified during operation by means
of the rotary selectors located on the right side of the chronothermostat.
Temperature T3 cannot be lower than temperature T2 or higher than 40 °C.
In Summer operation mode, the upper limit of temperature T3 is 30°C. When
this value is exceeded, T3 will take the OFF value, which will involve switching
the system off.
Temperature T2 cannot be higher than temperature T3 or lower than
temperature T1.
Temperature T1 cannot be higher than temperature T2 or lower than 2 °C.
If no customization has been made, the automatic operating mode will function
with the stored temperature profiles, i.e. the preset ones (refer to «Preset
programs» pag. 35). To customize the profiles, refer to «Chronothermostat
programming» pag. 35.
31