Télécharger Imprimer la page
Mitsubishi Electric LGH-F300RVX-E Manuel D'instructions
Mitsubishi Electric LGH-F300RVX-E Manuel D'instructions

Mitsubishi Electric LGH-F300RVX-E Manuel D'instructions

Masquer les pouces Voir aussi pour LGH-F300RVX-E:

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Lossnay Energy Recovery Ventilator
MODELS:
LGH-F300RVX-E, LGH-F470RVX-E, LGH-F600RVX-E
LGH-F1200RVX-E
Operating Instructions
Please read this manual carefully before use for proper and safe use.
Do not attempt to install the product by yourself.
Safety precautions
The following signs indicate that death or serious injury may be caused by failure to heed the precautions described below.
WARNING
Do not turn the unit on or off when flammable gas
has leaked.
(It could catch fire or cause explosion with sparks
released from electric contractor.)
Prohibited
Open windows to ventilate.
Do not modify or disassemble.
(It could cause fire, electric shock or injury.)
Do not
disassemble
Do not apply water to the unit and remote controller.
(Electrical shock can result.)
Do not wet
Do not poke your fingers or sticks into the air intake
and outlet while the product is operating.
(Failure to heed this warning may result in injury.)
Do not touch
CAUTION
Do not place a burning appliance in a place where
it is exposed directly to the wind from Lossnay.
(It could cause an accident as a result of incomplete
combustion.)
Do not operate with the "BY-PASS" when heating
the room in winter.
(Condensed water may drip from the unit and wet the
surface of ceiling.)
Do not use at a place where exposed to high
temperatures (104˚F(40˚C) or higher), naked flames,
or in environment with heavy fumes.
Prohibited
(It could cause fire.)
Do not use in an environment such as a chemical
factory, where hazardous gases such as acidic
gases, alkaline gases, organic solvent fumes, paint
fumes, or gases containing corrosive components
are generated.
(It could malfunction.)
Do not operate with wet hands.
(Electrical shock can result.)
Wet hands prohibited
Use the specified power supply and voltage.
(Use of incorrect power supply could cause fire or
electric shock.)
Make sure the power supply isolator is turned off
on the power distribution panel before starting
maintenance.
(It could cause electric shock or injury if it is turned on.)
When any abnormal conditions (burning smell, or
The instructions
given must be
others) are observed, stop operation, turn off the
followed.
power supply isolator on the power distribution
panel and consult your dealer.
(Continuing operation under such conditions could
cause, electric shock, fire, or damage.)
Securely install parts after maintenance.
(It could cause injury if parts fall.)
Put on gloves during maintenance.
(It could cause injury.)
Make sure the power supply isolator is turned off
on the power distribution panel when Lossnay is
not used for a long period of time.
(It could cause electric shock, power leakage, or fire as
a result of deteriorated insulation.)
This appliance is not intended for use by persons
The instructions
(including children) with reduced physical sensory
given must be
or mental capabilities, or lack of experience
followed.
and knowledge, unless they have been given
supervision or instruction concerning use of the
appliance by a person responsible for their safety.
Children should be supervised to ensure that they
do not play with the appliance.
Eng-1
1911876H33201
(For the user)

Publicité

loading

Sommaire des Matières pour Mitsubishi Electric LGH-F300RVX-E

  • Page 1 1911876H33201 Lossnay Energy Recovery Ventilator MODELS: LGH-F300RVX-E, LGH-F470RVX-E, LGH-F600RVX-E LGH-F1200RVX-E Operating Instructions (For the user) Please read this manual carefully before use for proper and safe use. Do not attempt to install the product by yourself. Safety precautions The following signs indicate that death or serious injury may be caused by failure to heed the precautions described below.
  • Page 2 Names of the parts Models LGH-F300 to F600RVX-E Model LGH-F1200RVX-E Lossnay core holder Lossnay core holder Control box Control box Air supply fan Maintenance cover Maintenance cover Air supply fan Fix piece Fix piece Lossnay core Damper plate Air exhaust fan Lossnay core Air filter Air exhaust fan...
  • Page 3 Operation (continued) n LOSSNAY ENERGY RECOVERY VENTILATE n AUTOMATIC VENTILATION setting setting The automatic ventilation mode automatically provides the correct ventilation for the conditions in the room. The following shows the Both fresh air supply and return air pass through the energy effect “By-pass”...
  • Page 4 * Temperature Exchange efficiency (%) are average of summer and winter condition. * Mitsubishi Electric measures products according to Japan Industrial Standard (JIS B 8628:2003), therefore P-Q curves are measured by chamber method. * On-site commissioning measurements by pitot tube method could be as much 20% difference from JIS test room conditions. If the measuring point is close to sources of turbulence like bends, contractions and dampers etc, it is difficult to measure air volume correctly.
  • Page 5 Ventilateur Lossnay à récupération d’énergie MODÈLES : LGH-F300RVX-E, LGH-F470RVX-E, LGH-F600RVX-E LGH-F1200RVX-E Mode d’emploi (pour l’utilisateur) Veuillez lire attentivement ce manuel avant l’usage afin d’utiliser correctement cet appareil en toute sécurité. N’essayez pas de monter vous-même ce produit. Consignes de sécurité...
  • Page 6 Nomenclature des pièces Modèles LGH-F300 à F600RVX-E Model LGH-F1200RVX-E Porte-noyau Lossnay Porte-noyau Lossnay Boîtier de commande Boîtier de commande Ventilateur d’alimentation d’air Couvercle d’entretien Couvercle d’entretien Ventilateur Pièce de fixation Pièce de fixation d’alimentation d’air Noyau Lossnay Plaque de registre Ventilateur d’évacuation d’air Noyau Lossnay Filtre à...
  • Page 7 Fonctionnement (suite) n Réglage de la VENTILATION À n Réglage de la VENTILATION AUTOMATIQUE Le mode de ventilation automatique fournit automatiquement la RÉCUPÉRATON D’ÉNERGIE LOSSNAY ventilation correcte selon les conditions de la pièce. L’effet de la L’air frais aspiré et l’air refoulé passent tous deux par les noyaux ventilation double flux dans différentes conditions est indiqué...
  • Page 8 * Le rendement de l’échange de température (%) sont dans la moyenne de l'état de l'été et l'hiver. * Mitsubishi Electric mesure les produits selon la norme industrielle japonaise (JIS B 8628: 2003), par conséquent les courbes P-Q sont mesurées selon la méthode de la chambre.

Ce manuel est également adapté pour:

Lgh-f470rvx-eLgh-f600rvx-eLgh-f1200rvx-e