Mitsubishi Lossnay Ventilator
MODEL
VL-50S
-E
2
VL-50ES
2
Installation Manual
Please ensure that the separate "Operating
Instructions" are handed over to the customer. Please
ensure that it is delivered to the customer.
■ Proper installation is necessary for the Lossnay to
perform at full potential and to ensure safety. Before
proceeding with the installation work, be sure to
read through these instructions.
■ The installation work must be done by an authorized
dealer or qualified contractor. Errors in installation
can lead to breakdowns and accidents.
■ Installation by the customer can lead to breakdowns
and accidents.
■ Electrical work must be done by a qualified and
licensed electrician employed by the dealer or
contractor.
■ The VL-50S
-E has a built-in plug and requires only
2
a simple plug-in to an electrical outlet. Accordingly,
no electrical work by a qualified and licensed
electrician is necessary.
■ If the supply cord is damaged, it must be replaced
by the manufacturer, its service agent or a similarly
qualified persons in order to avoid a hazard. (VL-
50S
-E only)
2
1. Safety precautions
Hazards created by mishandling and their
severity are indicated by the following
markers.
Warning:
This applies to mishandling or misoperation
of the product which could lead to a fatal or
serious injury.
Caution:
This applies to mishandling or misoperation
of the product which will lead to an injury or
damage to your home, household effects, etc.
All manuals and user guides at all-guides.com
(pull cord type)
-E
(wall switch type)
For Dealer and Contractor
Contents
1. Safety precautions .............................. 1
2. Dimensional outline drawing............... 3
3. List of included parts........................... 3
4. Before installation ............................... 4
5. Mounting instructions.......................... 5
5.1. Wall-hole construction .................. 5
5.2. Preparation before installation ..... 5
5.2.1 For horizontal mounting ........ 5
5.2.2 For vertical mounting ............. 7
5.3. Attaching the main unit ................ 9
5.4. Electrical work .............................. 10
5.5. Attaching the panel ...................... 10
5.6. Outdoor construction ................... 11
6. Checks after mounting........................ 12
7. Test run ............................................... 12
The explanation in this Installation Manual
is mainly for horizontal mounting of the
product but the unit can be mounted
vertically as well.
Warning
- Do not install the unit in
excessively hot areas (40°C or
Prohibited
more), near open flames, in areas
prone to oily smoke, or where it
could come in contact with organic
solvents.
- Fire could result.
- Do not disassemble the unit more
than necessary or modify it.
Do NOT
disassemble.
- Fire, electric shock or injury could
result.
- Do not let the unit get wet.
- Fire or electric shock could result.
Do not expose
to water
Eng-1